Abstract

Negative interference was established of the precipitating reagent (heparin/MnCl2) for the isolation of HDL in the determination of serum concentration of high density lipoproteins--cholesterol by the enzyme CHOD-PAP method. The combining of enzyme-substrate reagent with 8,0 mmol/l EDTA eliminated the negative interference, but induced a lightly manifested increase of the optical density regardless of cholesterol concentration. That is the reason, the calibration of the enzimatic method is recommended to be performen with cholesterol standards, pretreated with precipitating reagent, analogically to serum. The analytical significance of the modified method was studied as regards reproducibility (VK = 0,88% with investigation in series and VK = 4,57% with investigation in time) and of accurary (test of Lord, L = 0,073 less than Lp less than 0,05).

摘要

在采用CHOD - PAP酶法测定血清高密度脂蛋白胆固醇浓度时,已证实沉淀剂(肝素/MnCl₂)对分离高密度脂蛋白存在负干扰。酶底物试剂与8.0 mmol/L EDTA结合可消除负干扰,但无论胆固醇浓度如何,都会导致光密度略有增加。因此,建议酶法校准使用经沉淀剂预处理的胆固醇标准品,类似于血清。研究了改进方法在重现性(系列研究时VK = 0.88%,时间研究时VK = 4.57%)和准确性(洛德检验,L = 0.073,Lp<0.05)方面的分析意义。