Abstract

An analysis was made of the effect of sodium heparin solution on the determination of arterial blood PCO2, pH, and bicarbonate. Dilution of blood by heparin solution did not affect the pH of blood samples significantly but reduced the measured PCO2 and th calculated bicarbonate and base excess in direct proportion to the amount of dilution. Used in the usual quantities as an anticoagulant, lubricant, and filler of needle and syringe dead space, heparin solution caused a 17 per cent or greater reduction in PCO2 and bicarbonate in approximately 17 per cent of the arterial blood samples currently received for analysis in a university hospital laboratory. Such unrecognized errors could cause misinterpretations of acid-base status. Completely filling the sampling syringe with blood and using a small-gauge needle will reduce the error.

摘要

分析了肝素钠溶液对动脉血二氧化碳分压(PCO₂)、pH值和碳酸氢盐测定的影响。肝素溶液对血液的稀释对血样的pH值影响不显著,但会使测得的PCO₂以及计算得出的碳酸氢盐和碱剩余量与稀释量成正比降低。在通常用作抗凝剂、润滑剂以及填充针头和注射器死腔的用量下,肝素溶液在一所大学医院实验室目前接收用于分析的约17%的动脉血样本中,会导致PCO₂和碳酸氢盐降低17%或更多。这种未被识别的误差可能会导致对酸碱状态的错误解读。用血液完全充满采样注射器并使用小口径针头可减少误差。