Kenny M T, Albright K L, Sanderson R P
Appl Microbiol. 1970 Sep;20(3):371-3. doi: 10.1128/am.20.3.371-373.1970.
A sensitive and reproducible test for the determination of mumps serum-neutralizing antibody with Vero cells grown in disposable plastic microtiter plates is described. Serum end point titers obtained by this method showed excellent correlation with those obtained by the primary chick embryo tissue culture-hemadsorption tube test.