Arden G B, Carter R M, Macfarlan A
Br J Ophthalmol. 1984 Dec;68(12):878-84. doi: 10.1136/bjo.68.12.878.
The pattern electroretinogram has been found to be abnormal in all except three cases of maculopathy. This is in contrast to other electrophysiological tests, which are frequently unaffected. The degree of reduction is related to the loss of visual acuity. The response to focal flashes is less affected than the response to pattern.
除三例黄斑病变外,所有病例的图形视网膜电图均显示异常。这与其他电生理检查结果相反,其他电生理检查通常不受影响。降低程度与视力丧失有关。与对图形刺激的反应相比,对局部闪光的反应受影响较小。