Williams E D, Elliott H L, Boddy K, Haywood J K, Henderson I S, Harvey I, Kennedy A C
Clin Nephrol. 1980 Oct;14(4):198-200.
Whole body calcium, phosphorus and nitrogen have been measured by in vivo neutron activation analysis in patients with chronic renal failure, including 9 with dialysis encephalopathy. Aluminium was also activated by this procedure, but to the same radioactive product as that from phosphorus: its presence was therefore detected as an increase in the apparent total body phosphorus above that expected for a person with the same calcium content. Patients with dialysis encephalopathy had slightly more apparent phosphorus than others with chronic renal failure, although the difference was not statistically significant. This difference corresponded to an excess of aluminium not greater than 3.3 g(95% confidence limit) which places an upper limit on excess aluminium accumulation in this condition.
采用体内中子活化分析法对慢性肾衰竭患者(包括9例透析性脑病患者)的全身钙、磷和氮进行了测量。铝也可通过此方法被活化,但与磷产生相同的放射性产物:因此,其存在表现为表观全身磷含量高于具有相同钙含量的正常人预期值。透析性脑病患者的表观磷含量略高于其他慢性肾衰竭患者,尽管差异无统计学意义。这种差异对应的铝过量不超过3.3克(95%置信区间),这为此种情况下铝的过量蓄积设定了上限。