Frost D, Ramshad S M
Strahlentherapie. 1978 Sep;154(9):634-42.
Constructional radiation protection of X-ray examination rooms is perfectly settled by DIN 6812. The present study was intended to ascertain safe handling of X-rays in the surgical room. The measuring technique with LiF-dosimeters is described, and its results concerning the load to surgical personnel are communicated. Though, with frequent operations, the monthly turn-on time does not exceed thirty hours according to DIN 6811, the maximum permissible individual dose, nevertheless, will be exceeded. A practical representation of radiation load as a function of the turn-on time will facilitate to surgical personnel the estimation of dose. Then, spatial isodoses are shown by means of which the necessary protection equivalent of the building can be calculated. Even the minimum demand for a limitation of the controlled area to the surgical room does require lead-equivalent protection if the surgical room is small.
X射线检查室的建筑辐射防护已由德国工业标准DIN 6812完美解决。本研究旨在确定手术室中X射线的安全操作。描述了使用LiF剂量计的测量技术,并通报了其关于手术人员所受辐射量的结果。虽然按照DIN 6811,频繁手术时每月开机时间不超过30小时,但最大允许个人剂量仍会被超过。以开机时间为函数的辐射量实际表示将有助于手术人员估算剂量。然后,给出了空间等剂量线,据此可计算出建筑物所需的防护当量。如果手术室较小,即使将控制区域限制在手术室的最低要求也需要铅当量防护。