The results of pseudoisochromatic tests (TMC Ishihara, AOH-R-R) are relatively independent of age. In the Panel D-15, the NCT box 6/4 and the desaturated panel, ageing goes hand in hand with blue-yellow confusions. Fault-positive red-green confusions result from D8/2 examination. For the FM 100 Hue test and the Anomaloscope Nagel, the data found in the literature are confirmed. In nuclear cataract there is no increased shift of the Rayleigh equation towards the green, but towards the red.

摘要

假同色试验(TMC石原、AOH-R-R)的结果相对与年龄无关。在D-15色盘、NCT第6/4盒以及不饱和色盘中,衰老与蓝黄色混淆同时出现。D8/2检查会导致假阳性红绿色混淆。对于FM 100色调试验和纳格尔检偏镜,文献中所发现的数据得到了证实。在核性白内障中,瑞利方程没有向绿色方向的增加偏移,而是向红色方向偏移。