Esaias A O, Rhoden D L, Smith P B
J Clin Microbiol. 1982 Mar;15(3):419-24. doi: 10.1128/jcm.15.3.419-424.1982.
The Enteric-Tek wheel (Flow Laboratories), consisting of 14 different biochemical parameters for rapidly identifying Enterobacteriaceae, was evaluated and compared with the conventional method for completely identifying 301 enteric cultures, representing 36 species. The Enteric-Tek system correctly identified 264 (97.8%) of the 270 common or typical strains and 26 (83.9%) of the 31 unusual or atypical strains tested, demonstrating an overall identification accuracy rate of 96.3%. There were 80 (26.6%) correctly identified strains requiring additional tests. Of the 11 (3.6%) misidentifications, 5 (3 Klebsiella and 2 Salmonella strains) were correctly identified at the genus level. When 4,228 individual tests in the Enteric-Tek wheel were compared with the conventional tubed media, 96.4% of the tests agreed; urease, citrate, adonitol, and lactose agreed less than 97%. The Enteric-Tek system was found to be reliable and accurate in producing identifications at the genus and species level within 18 to 24 h.
对由14种不同生化参数组成、用于快速鉴定肠杆菌科细菌的Enteric-Tek轮式鉴定系统(弗洛实验室)进行了评估,并与用于完整鉴定36个菌种的301份肠道培养物的传统方法进行了比较。Enteric-Tek系统正确鉴定了所测试的270株常见或典型菌株中的264株(97.8%)以及31株不常见或非典型菌株中的26株(83.9%),总体鉴定准确率为96.3%。有80株(26.6%)正确鉴定的菌株需要进一步测试。在11次(3.6%)错误鉴定中,有5次(3株克雷伯菌属和2株沙门菌属菌株)在属水平上被正确鉴定。将Enteric-Tek轮式鉴定系统中的4228项单项测试与传统的试管培养基进行比较时,96.4%的测试结果一致;脲酶、柠檬酸盐、阿东糖醇和乳糖的测试结果一致性低于97%。结果发现,Enteric-Tek系统在18至24小时内对属和种水平的鉴定是可靠且准确的。