Blazevic D J, Mackay D L, Warwood N M
J Clin Microbiol. 1979 May;9(5):605-8. doi: 10.1128/jcm.9.5.605-608.1979.
The Micro-ID 4-h identification system for Enterobacteriaceae was compared to the API 20E overnight method, using 230 fresh clinical isolates and 74 stock cultures. Agreement was 97.8% for the clinical isolates and 93.2% for the stock cultures. Eighty-seven percent of primary culture plates containing gram-negative rods yielded sufficient growth to perform the 4-h Micro-ID identification on the same day the organisms were isolated.
采用230株新鲜临床分离株和74株标准菌株,将用于肠杆菌科细菌的Micro-ID 4小时鉴定系统与API 20E过夜鉴定方法进行比较。临床分离株的符合率为97.8%,标准菌株的符合率为93.2%。含有革兰氏阴性杆菌的原始培养平板中有87%产生了足够的生长量,能够在分离出细菌的同一天进行4小时的Micro-ID鉴定。