Barkai G, Mashiach S, Lanzer D, Kayam Z, Brish M, Goldman B
Obstet Gynecol. 1982 May;59(5):615-23.
During a 3-year period, 377 samples of amniotic fluid, free of blood and meconium and obtained from a total of 471 patients, were examined by the fluorescence polarization technique to estimate fetal lung maturity. Fluorescence polarization values of 287 samples from normal and abnormal pregnancies were correlated with gestational age. A total of 272 pregnancies comprising cases complicated by toxemia, placental insufficiency, placenta previa, premature contractions, and diabetes mellitus, and including a control group of 37, were studied to discern the effect of such pathologic conditions on the usual decline of fluorescence polarization (FP) values with increasing gestational age. No complicated pregnancy had values significantly different from those of the control group, except for pregnancies complicated by diabetes mellitus. The threshold of fetal lung maturity as related to respiratory distress syndrome (RDS) was determined in correlation with the lecithin: sphingomyelin (L:S) ratio. FP values of 0.311 +/- .005 corresponded to an L:S ratio of 2.0. An FP value of 0.316 +/- .005 is recommended as a practical threshold related to the clinical outcome of the newborn as regards RDS. The technique was found reliable, simple, and accurate and has been of great value in the antenatal diagnosis of fetal lung maturity.
在3年期间,对从471例患者获取的377份无血液和胎粪的羊水样本采用荧光偏振技术进行检测,以评估胎儿肺成熟度。对来自正常和异常妊娠的287份样本的荧光偏振值与孕周进行了相关性分析。共研究了272例妊娠,包括并发毒血症、胎盘功能不全、前置胎盘、早产宫缩和糖尿病的病例,以及一个37例的对照组,以了解这些病理状况对荧光偏振(FP)值随孕周增加而通常下降的影响。除并发糖尿病的妊娠外,没有复杂妊娠的荧光偏振值与对照组有显著差异。与呼吸窘迫综合征(RDS)相关的胎儿肺成熟度阈值是与卵磷脂:鞘磷脂(L:S)比值相关确定的。FP值0.311±0.005对应于L:S比值2.0。建议将FP值0.316±0.005作为与新生儿RDS临床结局相关的实用阈值。该技术被发现可靠、简单且准确,在胎儿肺成熟度的产前诊断中具有重要价值。