This review is drawn from a total of 3,714 knee arthroscopies carried out on patients from six clinics. The diagnostic value of arthroscopy at this site is established for it can improve prognostication, prevention and treatment of derangements of the knee. The complications of the procedure, both theoretical and in practice, have been considered by subdividing them into four groups. Firstly, the infection rate following arthroscopy alone was nil. Secondly, minor articular cartilage damage attributable to the instrument occurred in just over 2% of cases. This complication is more common when the technique is first being learned and is usually avoidable when experience has been gained. Thirdly, complications of a general nature included four cases of subcutaneous emphysema produced by the insufflation of gas, and 22 instances of an allergic skin reaction to the disinfectant preparation. Finally, failures in the technique itself resulted from the instrument bending or breaking when negotiating the condyles. This occurred on 26 occasions. In a further seven instances the fat pad was entered and distended in error, thus preventing examination of the joint. Overall, the complication rate was acceptable low and confirmed that arthroscopy can be safely applied clinically.
本综述源自对六个诊所的患者进行的总共3714例膝关节镜检查。关节镜检查在该部位的诊断价值已得到确立,因为它可以改善膝关节紊乱的预后、预防和治疗。该手术的并发症,无论是理论上的还是实际中的,都已通过将其细分为四组进行了考量。首先,仅进行关节镜检查后的感染率为零。其次,因器械导致的轻微关节软骨损伤在略超过2%的病例中出现。这种并发症在刚开始学习该技术时更为常见,而在积累经验后通常是可以避免的。第三,一般性质的并发症包括4例因气体注入导致的皮下气肿,以及22例对消毒制剂的过敏性皮肤反应。最后,技术本身的失误是由于器械在通过髁部时弯曲或断裂所致。这种情况发生了26次。另外有7例误穿并扩张了脂肪垫,从而妨碍了对关节的检查。总体而言,并发症发生率低到可以接受,证实了关节镜检查在临床上可以安全应用。