• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

A fluorescence polarization flow cytometer.

作者信息

Keene J P, Hodgson B W

出版信息

Cytometry. 1980 Sep;1(2):118-26. doi: 10.1002/cyto.990010205.

DOI:10.1002/cyto.990010205
PMID:7297345
Abstract

The effect of mitogens on the degree of polarization of the fluorescence from viable human lymphocytes, labeled with fluorescein, have been reported to be different in cells from subjects with malignant disease as compared with those from healthy donors. This has potential applications in the field of clinical diagnosis and a flow cytometer could be the instrument of choice for this purpose. We believe that such an instrument should be simple and easy to use and a flow cytometer was assembled with this in mind and with the object of gaining experience which would provide the basis for a future finalized design. The instrument is suitable for use in other biologic applications where polarization is of interest and also as a general purpose flow cytometer. Its main features, its characteristics and preliminary performance report are presented here.

摘要

相似文献

1
A fluorescence polarization flow cytometer.
Cytometry. 1980 Sep;1(2):118-26. doi: 10.1002/cyto.990010205.
2
A design for a real-time fluorescence polarization computer.一种实时荧光偏振计算机的设计。
Cytometry. 1980 Nov;1(3):204-11. doi: 10.1002/cyto.990010306.
3
Reduced gravity evaluation of potential spaceflight-compatible flow cytometer technology.对潜在的与航天飞行兼容的流式细胞仪技术进行失重环境评估。
Cytometry B Clin Cytom. 2005 Jul;66(1):1-9. doi: 10.1002/cyto.b.20057.
4
Identification of mitogen responding lymphocytes by fluorescence polarization.通过荧光偏振鉴定有丝分裂原反应性淋巴细胞。
Cytometry. 1981 Jan;1(4):265-71. doi: 10.1002/cyto.990010405.
5
Nationwide quality control trial on lymphocyte immunophenotyping and flow cytometer performance in Italy.意大利全国淋巴细胞免疫表型分析及流式细胞仪性能质量控制试验。
Cytometry. 1993;14(3):294-306. doi: 10.1002/cyto.990140310.
6
Analytical performance of an ultrasonic particle focusing flow cytometer.超声粒子聚焦流式细胞仪的分析性能
Anal Chem. 2007 Nov 15;79(22):8740-6. doi: 10.1021/ac071402t. Epub 2007 Oct 9.
7
Flow cytometry instrumentation in research and clinical laboratories.研究和临床实验室中的流式细胞仪检测技术。
Clin Lab Sci. 1993 May-Jun;6(3):167-73.
8
Analysis of early apoptotic events in individual cells by fluorescence intensity and polarization measurements.
Biochem Biophys Res Commun. 2002 Feb 8;290(5):1573-82. doi: 10.1006/bbrc.2002.6382.
9
Detection of lymphocyte stimulation by flow cytometry: differences in cells from patients with and without neoplasia.通过流式细胞术检测淋巴细胞刺激:肿瘤患者与非肿瘤患者细胞的差异。
Biomedicine. 1980 Dec;32(4):185-8.
10
Mitogen-induced changes in the fluorescence polarization of fluorescein in normal human lymphocytes: a membrane event?丝裂原诱导的正常人淋巴细胞中荧光素荧光偏振的变化:一种膜事件?
J Natl Cancer Inst. 1979 Aug;63(2):325-9.

引用本文的文献

1
Fluorescence anisotropy imaging in drug discovery.荧光各向异性成像在药物发现中的应用。
Adv Drug Deliv Rev. 2019 Nov-Dec;151-152:262-288. doi: 10.1016/j.addr.2018.01.019. Epub 2018 Feb 2.
2
The limitations of nonlinear fluorescence effect in super resolution saturated structured illumination microscopy system.超分辨率饱和结构照明显微系统中非线性荧光效应的局限性。
J Fluoresc. 2011 May;21(3):1075-82. doi: 10.1007/s10895-010-0780-4. Epub 2010 Dec 30.
3
Comparative studies of the uptake of daunorubicin in sensitive and resistant P388 cell lines by flow cytometry and biochemical extraction procedures.
通过流式细胞术和生化提取程序对柔红霉素在敏感和耐药P388细胞系中的摄取进行比较研究。
Cancer Chemother Pharmacol. 1983;11(2):113-6. doi: 10.1007/BF00254258.
4
Effects of irradiation on the interaction of fluorescent probes with lymphocytes.辐射对荧光探针与淋巴细胞相互作用的影响。
Am J Pathol. 1984 Feb;114(2):301-8.