Hammer M
Scand J Clin Lab Invest. 1978 Dec;38(8):707-16. doi: 10.1080/00365517809104877.
A radioimmunoassay for 8-arginine-vasopressin (AVP) measurement in human plasma has been developed and evaluated, using a commercial preparation of an antibody of AVP. Detection limit of the assay was 0.4 pg. A simple acetone extraction procedure gave a recovery of 65% of added [125I]AVP. The overall sensitivity in the assay was 1.0 pg/ml when 2 ml plasma samples were extracted. The antigenic sites of the employed antibody seemed to be a combination of amino acid residues in the tripeptide tail and the pentapeptide ring. This can explain that the antibody was almost completely insensitive to chemically or enzymatically degraded AVP. The inter-assay coefficient of variation for the control plasma pools averaged 17%. A good correlation to plasma osmolalities above 290 has been found. AVP level in recumbent subjects (n = 8) with plasma osmolalities in the normal range was 2.8 +/- 1.0 pg/ml (mean +/- SD) and in ambulatory subjects (n = 10) on ad lib. water intake 4.5 +/- 1.9 pg/ml (mean /+- SD).
利用抗8-精氨酸加压素(AVP)的商业化抗体制备了一种用于检测人血浆中AVP的放射免疫分析法并进行了评估。该分析方法的检测限为0.4皮克。简单的丙酮萃取程序使添加的[125I]AVP回收率达到65%。当萃取2毫升血浆样本时,该分析方法的总体灵敏度为1.0皮克/毫升。所用抗体的抗原位点似乎是三肽尾部和五肽环中氨基酸残基的组合。这可以解释该抗体对化学或酶促降解的AVP几乎完全不敏感。对照血浆池的批间变异系数平均为17%。已发现与高于290的血浆渗透压有良好的相关性。血浆渗透压在正常范围内的卧位受试者(n = 8)的AVP水平为2.8±1.0皮克/毫升(平均值±标准差),随意饮水的活动受试者(n = 10)的AVP水平为4.5±1.9皮克/毫升(平均值±标准差)。