Suppr超能文献

离子色谱法作为测定人血清中总钠和总钾的潜在参考方法。

Ion chromatography as potential reference methodology for the determination of total sodium and potassium in human serum.

作者信息

Thienpont L M, Van Nuwenborg J E, Stöckl D

机构信息

Laboratorium voor Analytische Chemie, University of Ghent, Belgium.

出版信息

J Chromatogr A. 1995 Jul 7;706(1-2):443-50. doi: 10.1016/0021-9673(95)00152-d.

Abstract

The potential of ion chromatography to serve as a new reference method principle for the determination of total sodium and potassium in human serum was investigated. Sample pretreatment consisted of acidic dilution and filtration and detection was based on conductivity. Methods for the separate and simultaneous determination of both analytes were investigated. Further, the influence of calibration (using either a single-point calibration or a standard curve) on method imprecision, inaccuracy and analysis time was examined. The best method performance was achieved by separate analysis using single-point calibration with bracketing analysis scheme. For this variant, the mean total coefficient of variation for sodium and potassium was 1.0% and the mean method bias was -0.2% for sodium and 2% for potassium, as determined with three control materials from the National Institute of Standards and Technology. Our results are comparable to those of reference methods based on flame atomic emission spectrometry. Therefore, we consider ion chromatography as a valuable reference methodology for the determination of total sodium potassium in human serum.

摘要

研究了离子色谱法作为测定人血清中总钠和总钾的新参考方法原理的潜力。样品预处理包括酸性稀释和过滤,检测基于电导率。研究了分别和同时测定两种分析物的方法。此外,还考察了校准(使用单点校准或标准曲线)对方法精密度、准确性和分析时间的影响。采用单点校准和括号分析方案进行单独分析,可获得最佳的方法性能。对于该变体,使用美国国家标准与技术研究院的三种对照物质测定,钠和钾的平均总变异系数分别为1.0%,钠的平均方法偏差为-0.2%,钾的平均方法偏差为2%。我们的结果与基于火焰原子发射光谱法的参考方法相当。因此,我们认为离子色谱法是测定人血清中总钠和钾的有价值的参考方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验