Abstract

Results from the Bac-T-Screen (BTS) of fresh urine specimens were compared with the BTS results obtained when the same urine specimens had been held at room temperature for 24 h. Of the 246 specimens studied, 43 were initially BTS positive, 11 were false-negative, and 39 had greater than or equal to 10(5) CFU/ml. After 24 h at room temperature an additional 60 specimens had greater than or equal to 10(5) CFU/ml, of which only 16 were BTS positive; 10 specimens still gave false-negative results, and the number of false-positive specimens increased by only 6.5% of all specimens. For significant specimens (containing greater than or equal to 10(5) CFU of probable pathogens per ml), the predictive value of a negative test changed by only 0.1% (99.5 to 99.4%), whereas the sensitivity of the test remained at 96.4% for incubated specimens. Of those specimens that developed greater than or equal to 10(5) CFU/ml in vitro, 85% contained gram-negative bacilli. Neither bacteria grown in vitro nor urine specimens from normal females containing greater than or equal to 10(5) CFU/ml were positive with the BTS. For reasons not entirely understood, the BTS system may be unique in its ability to discriminate between bacteria which represent true bacteriuria and those which are present because of contamination, possibly due to other cellular elements present in infection-related bacteriuria, namely leukocytes and sloughed bladder epithelial cells.

摘要

将新鲜尿液标本的Bac-T-Screen(BTS)检测结果与相同尿液标本在室温下保存24小时后获得的BTS结果进行比较。在所研究的246份标本中,最初有43份BTS检测呈阳性,11份为假阴性,39份每毫升含有大于或等于10⁵CFU。在室温下放置24小时后,又有60份标本每毫升含有大于或等于10⁵CFU,其中只有16份BTS检测呈阳性;10份标本仍给出假阴性结果,假阳性标本数量仅增加了所有标本的6.5%。对于有意义的标本(每毫升含有大于或等于10⁵CFU可能的病原体),阴性检测的预测值仅改变了0.1%(从99.5%降至99.4%),而对于培养后的标本,检测的敏感性仍保持在96.4%。在体外培养出每毫升大于或等于10⁵CFU的标本中,85%含有革兰氏阴性杆菌。体外培养出的细菌以及每毫升含有大于或等于10⁵CFU的正常女性尿液标本,BTS检测均为阴性。由于尚未完全理解的原因,BTS系统在区分代表真正菌尿的细菌和因污染而存在的细菌方面可能具有独特能力,这可能是由于感染相关菌尿中存在的其他细胞成分,即白细胞和脱落的膀胱上皮细胞。

相似文献

5
Rapid bioluminescence method for bacteriuria screening.用于菌尿筛查的快速生物发光法
J Clin Microbiol. 1989 Apr;27(4):716-20. doi: 10.1128/jcm.27.4.716-720.1989.
6
Evaluation of the FiltraCheck-UTI for detection of bacteriuria.
Diagn Microbiol Infect Dis. 1990 Jul-Aug;13(4):289-95. doi: 10.1016/0732-8893(90)90019-r.
7
Screening for urinary tract infection using Bac-T-Screen bacteriuria device.
Urology. 1986 May;27(5):424-8. doi: 10.1016/0090-4295(86)90407-3.
8
Evaluation of a two-minute test for urine screening.尿液筛查两分钟测试的评估
J Clin Microbiol. 1983 Sep;18(3):697-701. doi: 10.1128/jcm.18.3.697-701.1983.
10
Detection of bacteriuria and pyuria within two minutes.两分钟内检测出菌尿和脓尿。
J Clin Microbiol. 1985 Apr;21(4):578-81. doi: 10.1128/jcm.21.4.578-581.1985.

本文引用的文献

3
Diagnosis of coliform infection in acutely dysuric women.急性排尿困难女性大肠菌感染的诊断
N Engl J Med. 1982 Aug 19;307(8):463-8. doi: 10.1056/NEJM198208193070802.
4
Screening of urine cultures by three automated systems.通过三种自动化系统对尿培养进行筛查。
J Clin Microbiol. 1982 Mar;15(3):468-74. doi: 10.1128/jcm.15.3.468-474.1982.
5
Evaluation of the B-D urine culture kit.B-D尿液培养试剂盒的评估
J Clin Microbiol. 1981 Dec;14(6):628-30. doi: 10.1128/jcm.14.6.628-630.1981.
6
Rapid semiautomated screening and processing of urine specimens.尿液标本的快速半自动筛查与处理
J Clin Microbiol. 1980 Mar;11(3):220-5. doi: 10.1128/jcm.11.3.220-225.1980.
9
Evaluation of a two-minute test for urine screening.尿液筛查两分钟测试的评估
J Clin Microbiol. 1983 Sep;18(3):697-701. doi: 10.1128/jcm.18.3.697-701.1983.
10
Clinical laboratory evaluation of a urine screening device.尿液筛查设备的临床实验室评估
J Clin Microbiol. 1983 Sep;18(3):674-9. doi: 10.1128/jcm.18.3.674-679.1983.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验