Suppr超能文献

在需氧BacT/Alert血培养瓶中培养5毫升与10毫升血液的对照评估。

Controlled evaluation of 5 versus 10 milliliters of blood cultured in aerobic BacT/Alert blood culture bottles.

作者信息

Weinstein M P, Mirrett S, Wilson M L, Reimer L G, Reller L B

机构信息

Department of Medicine, University of Medicine and Dentistry of New Jersey-Robert Wood Johnson Medical School, New Brunswick 08901.

出版信息

J Clin Microbiol. 1994 Sep;32(9):2103-6. doi: 10.1128/jcm.32.9.2103-2106.1994.

Abstract

Bottles developed for use in the BacT/Alert automated blood culture system (Organon Teknika Corp., Durham, N.C.) can accept up to 10 ml of blood without falling below a 1:5 ratio of blood to broth. We compared the yield and speed of detection of microorganisms in 13,128 adequately filled, paired, aerobic bottles inoculated with 5 versus 10 ml of blood at three university hospitals. A total of 798 microorganisms causing sepsis grew in one or both bottles. The overall recovery of microorganisms from 10-ml samples exceeded that from 5-ml samples (P < 0.001); the increased yield attributed to the additional 5 ml in the samples was 7.2%. The increased yield from 10-ml inocula was most marked for Escherichia coli (P < 0.01) and other members of the family Enterobacteriaceae (P < 0.001). Ten-milliliter samples did not yield more gram-positive bacteria, nonfermentative gram-negative rods, or yeasts. When both bottles were positive, the bottles inoculated with 10 ml of blood showed growth sooner (P < 0.001). Earlier detection with 10-ml inocula was especially notable for coagulase-negative staphylococci (P < 0.001), streptococci (P < 0.001), E. coli (P < 0.025), and other members of the family Enterobacteriaceae (P < 0.025). We conclude that an increase in the volume of blood inoculated into BacT/Alert aerobic blood culture bottles from 5 to 10 ml will increase the overall yield and the speed of detection of clinically important blood pathogens.

摘要

为BacT/Alert自动血培养系统(Organon Teknika公司,北卡罗来纳州达勒姆)设计的培养瓶,能够容纳多达10毫升血液,且血液与肉汤的比例不会低于1:5。我们在三家大学医院比较了13128对充分填充且配对的需氧培养瓶中,接种5毫升和10毫升血液时微生物的检出率和检测速度。共有798种导致败血症的微生物在一个或两个培养瓶中生长。从10毫升样本中微生物的总体回收率超过了5毫升样本(P<0.001);样本中额外5毫升血液导致的回收率提高了7.2%。接种10毫升血液时回收率的提高在大肠杆菌(P<0.01)和肠杆菌科其他成员中最为显著(P<0.001)。10毫升样本中革兰氏阳性菌、非发酵革兰氏阴性杆菌或酵母菌的回收率并没有更高。当两个培养瓶均呈阳性时,接种10毫升血液的培养瓶生长更快(P<0.001)。接种10毫升血液时更早检测到细菌,在凝固酶阴性葡萄球菌(P<0.001)、链球菌(P<0.001)、大肠杆菌(P<0.025)和肠杆菌科其他成员中尤为明显(P<0.025)。我们得出结论,将接种到BacT/Alert需氧血培养瓶中的血液量从5毫升增加到10毫升,将提高临床重要血液病原体的总体回收率和检测速度。

相似文献

5
Comparison of BacT/Alert with Signal blood culture system.BacT/Alert与信号血培养系统的比较。
J Clin Microbiol. 1995 Feb;33(2):313-7. doi: 10.1128/jcm.33.2.313-317.1995.

引用本文的文献

2
Bacteremia in Severe Mastitis of Dairy Cows.奶牛严重乳腺炎中的菌血症
Microorganisms. 2023 Jun 23;11(7):1639. doi: 10.3390/microorganisms11071639.

本文引用的文献

2
Inactivation of penicillins by Thiol broth.硫醇肉汤对青霉素的灭活作用。
J Clin Microbiol. 1982 Nov;16(5):982-4. doi: 10.1128/jcm.16.5.982-984.1982.
8
Blood cultures.血培养
Ann Intern Med. 1987 Feb;106(2):246-53. doi: 10.7326/0003-4819-106-2-246.
9
Blood cultures: issues and controversies.血培养:问题与争议
Rev Infect Dis. 1986 Sep-Oct;8(5):792-802. doi: 10.1093/clinids/8.5.792.