Vaz De Lima L R, Hoshino-Shimizu S, de Souza V A, Pannuti C S, Andrade Júnior H F, Sumita L M, Ferreira A W
Seção de Imunologia, Instituto Adolfo Lutz, São Paulo, Brazil.
Rev Inst Med Trop Sao Paulo. 1994 Mar-Apr;36(2):139-47. doi: 10.1590/s0036-46651994000200008.
A Dot-ELISA using a measles virus (MV) antigen obtained by sodium deoxycholate treatment was standardized and evaluated for IgM and IgG antibody detection in measles patients and measles-vaccinated subjects. A total of 192 serum samples were studied, comprising 47 from patients with acute and convalescent measles, 55 from 9-month old children prior to measles vaccination and 41 from children of the same age after vaccination, and 49 from patients with unrelated diseases. The diagnostic performances of the IgG Dot-ELISA and IgG immunofluorescence test (IFT) were found to be close, varying from 0.97 to 1.00 in sensitivity and the specificities were maximum (1.00). Nevertheless, the sensitivity of the IgM Dot-ELISA (0.85) was higher than that (0.63) of the IgM IFT, although both assays had comparably high (1.00) specificities. The IgM Dot-ELISA in particular proved to be more sensitive in relation to other assays studied by revealing antibodies in 80.0% (12/15) of vaccinated children on the 15th day after immunization. In contrast, the IgM IFT, failed to detect antibodies in the same group of vaccinated children. The stability of the MV antigen was longer than that of the IFT antigen, and the reproducibility of the Dot-Elisa was satisfactory.
使用经脱氧胆酸钠处理获得的麻疹病毒(MV)抗原的斑点酶联免疫吸附测定(Dot-ELISA)进行了标准化,并对麻疹患者和接种麻疹疫苗的受试者的IgM和IgG抗体检测进行了评估。共研究了192份血清样本,包括47份急性和恢复期麻疹患者的样本、55份9个月大未接种麻疹疫苗儿童的样本、41份同年龄接种疫苗后儿童的样本以及49份患有无关疾病患者的样本。发现IgG Dot-ELISA和IgG免疫荧光试验(IFT)的诊断性能相近,敏感性在0.97至1.00之间,特异性均为最高(1.00)。然而,IgM Dot-ELISA的敏感性(0.85)高于IgM IFT(0.63),尽管两种检测方法的特异性都相当高(1.00)。特别是IgM Dot-ELISA在研究的其他检测方法中表现得更为敏感,在免疫后第15天,80.0%(12/15)接种疫苗的儿童中检测到了抗体。相比之下,IgM IFT在同一组接种疫苗的儿童中未能检测到抗体。MV抗原的稳定性比IFT抗原更长,Dot-ELISA的重复性也令人满意。