Dion I, Baquey C, Monties J R, Havlik P
INSERM U. 306, Université de Bordeaux II, France.
Biomaterials. 1993;14(2):122-6. doi: 10.1016/0142-9612(93)90222-n.
Ti6A14V alloy has been mainly used as a biomaterial in the orthopaedic field. The present study describes the surface state of the Ti6A14V material and evaluates its in vitro haemocompatibility in terms of protein adsorption, platelet retention and haemolysis. The behaviour of the Ti6A14V alloy towards albumin and fibrinogen was compared to that of a reference medical-grade elastomer. The platelet retention test gave better results than those achieved with the elastomer. The haemolysis percentage of the alloy was almost zero. These results indicate that the Ti6A14V alloy is well tolerated by blood.
Ti6A14V合金主要用作骨科领域的生物材料。本研究描述了Ti6A14V材料的表面状态,并从蛋白质吸附、血小板滞留和溶血方面评估了其体外血液相容性。将Ti6A14V合金对白蛋白和纤维蛋白原的行为与参考医用级弹性体的行为进行了比较。血小板滞留测试的结果比弹性体的更好。该合金的溶血率几乎为零。这些结果表明,血液对Ti6A14V合金耐受性良好。