Moore C G, Epley D, Milne S T, Morrison J C
Kenneth C. Swan Ocular Neurobiology Laboratory, Casey Eye Institute, Portland, OR 97201-4197, USA.
Curr Eye Res. 1995 Aug;14(8):711-7. doi: 10.3109/02713689508998499.
To study the optic neuropathy associated with glaucoma, a system for accurate, reliable, and non-invasive monitoring of intraocular pressure (IOP) is required. Of particular interest is the effect of sampling frequency on IOP. To address this issue, ten adult male brown Norway rats (group 1) were acclimatized to a 12-h/12-h light/dark cycle. On 20 days over a 30-day period, rats were anesthetized with short-acting isoflurane (Forane) inhalant anesthesia and IOP for each eye was determined by averaging 15 valid individual readings obtained with a TonoPen 2 tonometer. The last 12 measurement sessions were performed on a daily basis. To determine the minimum tolerable interval between IOP measurement sessions, a second group of 10 animals (group 2) was acclimatized in the same manner as group 1, and IOP was measured every 4 days over a period of 80 days. Next, IOP was measured every 4 days over a period of 28 days, and finally, every 2 days over a period of 19 days. For all group 1 measurements, there was no statistically significant difference between the right and left eye IOP, 14.75 +/- 1.08 (SEM) and 14.90 +/- 1.09 mm Hg, respectively. However, daily measurements produced a steady decrease in IOP and gradual weight loss. For group 2, overall mean right and left eye IOPs were 15.24 +/- 1.28 (SEM) and 15.12 +/- 1.26, respectively and were not significantly different.(ABSTRACT TRUNCATED AT 250 WORDS)
为研究与青光眼相关的视神经病变,需要一种准确、可靠且无创的眼内压(IOP)监测系统。采样频率对眼内压的影响尤其令人关注。为解决此问题,将十只成年雄性挪威棕色大鼠(第1组)置于12小时光照/12小时黑暗的周期中适应环境。在30天内的20天里,用短效异氟烷(福仑)吸入麻醉大鼠,并用托诺笔2眼压计通过平均15次有效个体读数来测定每只眼睛的眼内压。最后12次测量每天进行。为确定眼内压测量之间的最小可耐受间隔,第二组10只动物(第2组)以与第1组相同的方式适应环境,并在80天内每4天测量一次眼内压。接下来,在28天内每4天测量一次眼内压,最后在19天内每2天测量一次。对于第1组的所有测量,右眼和左眼的眼内压之间无统计学显著差异,分别为14.75±1.08(标准误)和14.90±1.09毫米汞柱。然而,每日测量导致眼内压稳步下降和体重逐渐减轻。对于第2组,右眼和左眼的总体平均眼内压分别为15.24±1.28(标准误)和15.12±1.26,且无显著差异。(摘要截断于250字)