Suppr超能文献

甲氨蝶呤治疗的类风湿关节炎患者中,法语版关节炎影响测量量表2(AIMS2)的效度、信度及对变化的敏感度

Validity, reliability, and sensitivity to change of a French version of the arthritis impact measurement scales 2 (AIMS2) in patients with rheumatoid arthritis treated with methotrexate.

作者信息

Pouchot J, Guillemin F, Coste J, Brégeon C, Sany J

机构信息

Department of Internal Medicine, Hôpital Louis Mourier, Colombes, France.

出版信息

J Rheumatol. 1996 Jan;23(1):52-60.

PMID:8838508
Abstract

OBJECTIVE

To develop and validate a cross cultural version of the Arthritis Impact Measurement Scales 2 (AIMS2) to be used by French speaking populations.

METHODS

A French version of the AIMS2 was obtained using back translation, committee review, and pretesting. The French AIMS2 was studied in 127 patients with rheumatoid arthritis (RA) about to receive therapy with methotrexate (MTX). Construct validity of the questionnaire was assessed by factor analysis. Convergent validity was evaluated by correlation coefficients with joint counts, pain assessment, and sedimentation rate. Reliability was assessed by test-retest procedure at a 10-day interval, Cronbach's coefficients of internal consistency, and within scale factor analyses. Sensitivity to change after 12 and 24 weeks of therapy with MTX was assessed with computation of standardized response means (SRM) and paired t test comparisons.

RESULTS

Factor analyses of the French version clearly identified the same scales of the AIMS2, except for the walking and bending scale which loaded on several factors. Convergent validity of the physical and symptom components of the instrument was demonstrated by significant correlations with clinical and laboratory features. All the scales were reliable (intraclass correlation coefficients: 0.65 to 0.90; percentage of explained variance larger than 50% in all but one scale; Cronbach's alpha: 0.70 to 0.90). Sensitivity to change was demonstrated in 11 of the 12 scales (SRM: 0.30 to 0.77). Most of the improvement was noted by Week 12.

CONCLUSIONS

This cross cultural adaptation of AIMS2 in French is valid, reliable, and responsive in patients with RA in whom MTX therapy is instituted. It would permit international comparison studies. This study provides evidence for construct validity and responsiveness of the original version of the AIMS2, not demonstrated previously.

摘要

目的

开发并验证关节炎影响测量量表2(AIMS2)的跨文化版本,供说法语人群使用。

方法

采用回译、委员会审核和预测试获得AIMS2的法语版本。对127例即将接受甲氨蝶呤(MTX)治疗的类风湿关节炎(RA)患者进行了法语版AIMS2的研究。通过因子分析评估问卷的结构效度。通过与关节计数、疼痛评估和血沉的相关系数评估收敛效度。通过间隔10天的重测程序、克朗巴赫内部一致性系数和量表内因子分析评估信度。通过计算标准化反应均值(SRM)和配对t检验比较评估MTX治疗12周和24周后的变化敏感性。

结果

法语版的因子分析清楚地确定了AIMS2的相同量表,但行走和弯曲量表加载在几个因子上除外。该工具的身体和症状成分的收敛效度通过与临床和实验室特征的显著相关性得到证明。所有量表都是可靠的(组内相关系数:0.65至0.90;除一个量表外,所有量表的解释方差百分比均大于50%;克朗巴赫α系数:0.70至0.90)。12个量表中有11个表现出对变化的敏感性(SRM:0.30至0.77)。大部分改善在第12周时已显现。

结论

AIMS2的这种法语跨文化改编在接受MTX治疗的RA患者中是有效、可靠且有反应性的。它将允许进行国际比较研究。本研究为AIMS2原始版本的结构效度和反应性提供了证据,此前未得到证实。