基于基于挠度标准的侧面安全气囊系统的参数研究。

A parametric study of a side airbag system to meet deflection based criteria.

作者信息

Håland Y, Pipkorn B

机构信息

Autoliv AB, Vårgårda, Sweden.

出版信息

J Biomech Eng. 1996 Aug;118(3):412-9. doi: 10.1115/1.2796025.

Abstract

A side airbag system comprising of 12 liter bag to cover the BioSid chest and the abdomen down to the arm rest level, and 75 mm of padding to cover the pelvic/thigh area was evaluated by a series of sled tests at two different velocities, 10 m/s and 12 m/s. The initial bag (over) pressure was varied from 0 to 80 kPa and the bag ventilation area was varied from zero to 1500 mm2. Compressed air was used to fill the bag. It was found that the ventilation of the bag reduced the maximum chest deflection by 30 percent and the maximum viscous criterion, VC, by 50 percent (comparison was made with the same bag without ventilation). A suitable initial bag (over) pressure was found to be about 50 kPa, when the loading of the abdomen was also taken into consideration. The results indicate that the chest deflection is proportioned to the door average velocity (during the first 20 ms of deflection) to the power of about 2 and that the VC is proportional to the same velocity to the power of about 4. It was also found that a 12 liter ventilated side airbag resulted in 30-40 percent lower chest deflection and about 60 percent lower VC than 50 mm of chest padding (Ethafoam 220).

摘要

一种侧面安全气囊系统,由一个12升的气囊组成,用于覆盖BioSid的胸部和腹部直至扶手高度,以及75毫米的衬垫用于覆盖骨盆/大腿区域。该系统在10米/秒和12米/秒这两种不同速度下进行了一系列雪橇试验。初始气囊(过)压力在0至80千帕之间变化,气囊通风面积在0至1500平方毫米之间变化。使用压缩空气填充气囊。结果发现,气囊通风使最大胸部偏移减少了30%,最大粘性标准(VC)降低了50%(与未通风的相同气囊进行比较)。当考虑腹部负荷时,发现合适的初始气囊(过)压力约为50千帕。结果表明,胸部偏移与车门平均速度(在偏移的前20毫秒内)的约2次方成正比,VC与相同速度的约4次方成正比。还发现,一个12升的通风侧面安全气囊比50毫米的胸部衬垫(Ethafoam 220)使胸部偏移降低30%-40%,VC降低约60%。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验