Suppr超能文献

荧光BACTEC 9000 MB系统、Septi-Chek AFB系统和罗-琴培养基检测分枝杆菌的比较

Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria.

作者信息

van Griethuysen A J, Jansz A R, Buiting A G

机构信息

Department of Clinical Microbiology, St. Elisabeth Hospital, Tilburg, The Netherlands.

出版信息

J Clin Microbiol. 1996 Oct;34(10):2391-4. doi: 10.1128/jcm.34.10.2391-2394.1996.

Abstract

The newly developed fluorescent BACTEC 9000 MB system for automated culture of mycobacteria was compared with the Septi-Chek AFB system and Lowenstein-Jensen medium (LJ). A total of 2,005 clinical specimens were included in the study. Mycobacteria were isolated from 202 (10.1%) specimens, including 155 Mycobacterium tuberculosis complex isolates and 47 Mycobacteria other than M. tuberculosis isolates. Of 131 isolates detected by the BACTEC system, the Septi-Chek AFB system, or both, 120 (91.6%) were detected by the BACTEC system and 105 (80.2%) were detected by the Septi-Chek AFB system (P < 0.02). The recovery rate in the BACTEC system compared with that in the Septi-Chek AFB system was significantly higher for M. tuberculosis complex isolates (P < 0.005) and for isolates from acid-fast smear-negative specimens (P < 0.01). Of 148 isolates detected by the BACTEC system, LJ, or both, 142 (95.9%) were detected by the BACTEC system and 118 (79.9%) were detected by LJ (P < 0.001). The recovery rate in the BACTEC system compared with that on LJ was significantly higher for M. tuberculosis complex isolates (P < 0.001). The BACTEC system detected more mycobacteria from both smear-positive and smear-negative specimens than LJ. The mean times to detection of mycobacteria were 17.6 days for the BACTEC system, 26.0 days for the Septi-Chek AFB system, and 29.4 days for LJ. The BACTEC fluorescent 9000 MB system is a rapid, sensitive, and efficient method for the isolation of mycobacteria.

摘要

将新开发的用于分枝杆菌自动培养的荧光BACTEC 9000 MB系统与Septi-Chek AFB系统和罗氏培养基(LJ)进行了比较。该研究共纳入2005份临床标本。从202份(10.1%)标本中分离出分枝杆菌,其中包括155株结核分枝杆菌复合群分离株和47株非结核分枝杆菌分离株。在通过BACTEC系统、Septi-Chek AFB系统或两者检测到的131株分离株中,BACTEC系统检测到120株(91.6%),Septi-Chek AFB系统检测到105株(80.2%)(P<0.02)。与Septi-Chek AFB系统相比,BACTEC系统对结核分枝杆菌复合群分离株(P<0.005)和抗酸涂片阴性标本分离株(P<0.01)的回收率显著更高。在通过BACTEC系统、LJ或两者检测到的148株分离株中,BACTEC系统检测到142株(95.9%),LJ检测到118株(79.9%)(P<0.001)。与LJ相比,BACTEC系统对结核分枝杆菌复合群分离株的回收率显著更高(P<0.001)。BACTEC系统从涂片阳性和涂片阴性标本中检测到的分枝杆菌均多于LJ。分枝杆菌的平均检测时间为:BACTEC系统17.6天,Septi-Chek AFB系统26.0天,LJ 29.4天。BACTEC荧光9000 MB系统是一种快速、灵敏且高效的分枝杆菌分离方法。

相似文献

引用本文的文献

7
Modern laboratory diagnosis of mycobacterial infections.分枝杆菌感染的现代实验室诊断
J Clin Pathol. 2000 Oct;53(10):727-32. doi: 10.1136/jcp.53.10.727.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验