Suppr超能文献

Caltrac加速度计对跑步、竞走和踏步的能量消耗估计。

Energy expenditure estimates of the Caltrac accelerometer for running, race walking, and stepping.

作者信息

Swan P D, Byrnes W C, Haymes E M

机构信息

Department of Exercise Science and Physical Education, Arizona State University, Tempe 85287-0701, USA.

出版信息

Br J Sports Med. 1997 Sep;31(3):235-9. doi: 10.1136/bjsm.31.3.235.

Abstract

OBJECTIVE

To examine the accuracy of the Caltrac accelerometer for estimating energy expenditure (EE) during three exercise modes.

METHODS

A subset of 31 women (mean (SEM) age 22.6 (5) years) as selected from a training study comparing various physiological parameters during race walking, running, and stepping. Subjects each performed mode specific graded exercise tests to peak VO2. Regression equations for VO2 v heart rate (HR) were generated from each individual's test data. EE (kcal and kJ) was estimated for each VO2 value based on the respiratory exchange ratio, and kcal v HR regression equations were generated to predict EE from each subject's HR data (EE-HR). HR in the field was monitored by telemetry, and two Caltrac monitors, one set for EE and one to give counts, were attached to a belt over opposite hips.

RESULTS

EE-HR was not significantly different across exercise modes. Caltrac overestimated EE (P < 0.01) in runners (14%) and walkers (19%) but underestimated EE in steppers by about 10% (P = 0.12).

CONCLUSIONS

The Caltrac is a reliable instrument but it did not accurately distinguish EE in running, race walking, or stepping in a group of young women.

摘要

目的

研究Caltrac加速度计在三种运动模式下估算能量消耗(EE)的准确性。

方法

从一项训练研究中选取31名女性(平均(标准误)年龄22.6(5)岁)作为子集,该研究比较了竞走、跑步和踏步过程中的各种生理参数。受试者分别进行特定模式的分级运动测试至峰值摄氧量(VO2)。根据每个个体的测试数据生成VO2与心率(HR)的回归方程。基于呼吸交换率为每个VO2值估算EE(千卡和千焦),并生成千卡与HR的回归方程以根据每个受试者的HR数据预测EE(EE-HR)。通过遥测监测现场的HR,并将两个Caltrac监测器,一个设置用于EE,一个用于计数,分别系在相对臀部上方的腰带上。

结果

不同运动模式下的EE-HR无显著差异。Caltrac高估了跑步者(14%)和步行者(19%)的EE(P < 0.01),但低估了踏步者的EE约10%(P = 0.12)。

结论

Caltrac是一种可靠的仪器,但在一组年轻女性中,它不能准确区分跑步、竞走或踏步时的EE。

相似文献

7
Validity of the Nike+ device during walking and running.耐克+设备在行走和跑步时的有效性。
Int J Sports Med. 2010 Feb;31(2):101-5. doi: 10.1055/s-0029-1242810. Epub 2009 Dec 21.
9
Validity of uniaxial accelerometry during activities of daily living in children.儿童日常生活活动中单轴加速度计的有效性
Eur J Appl Physiol. 2004 Mar;91(2-3):259-63. doi: 10.1007/s00421-003-0983-3. Epub 2003 Oct 21.

引用本文的文献

本文引用的文献

4
The measurement of daily energy expenditure--an evaluation of some techniques.
Am J Clin Nutr. 1980 May;33(5):1155-64. doi: 10.1093/ajcn/33.5.1155.
5
Portable accelerometer device for measuring human energy expenditure.
IEEE Trans Biomed Eng. 1981 Jun;28(6):467-71. doi: 10.1109/TBME.1981.324820.
9
A biomechanical analysis of racewalking gait.
Med Sci Sports Exerc. 1986 Aug;18(4):446-53.