Greca G L, Botti E, Biasioli S, Coli U, Fabris A, Gaianigo P L, Pisani E
Proc Eur Dial Transplant Assoc. 1976;12:546-50.
In eighteen months, eleven Sparks mandrils have been implanted in ten patients who presented serious vascular access problems. So far nine mandrils have been anastomosed and six are functioning. In one patient the apparatus, inserted in the right leg, clotted after 108 dialyses and was reinserted in the left arm; after a further forty dialyses the patient died from causes not connected with dialysis. Another patient's Sparks mandril thrombosed from infection on the fourth post-operative day. Using a single needle apparatus, 693 dialyses have been carried out with particular problems either for the patients or the grafts.
在18个月的时间里,已将11个斯帕克斯人造血管植入10名存在严重血管通路问题的患者体内。到目前为止,9个人造血管已完成吻合,其中6个仍在发挥功能。有1名患者的人造血管植入右腿,在进行了108次透析后出现血栓形成,之后被重新植入左臂;在又进行了40次透析后,该患者死于与透析无关的原因。另1名患者的斯帕克斯人造血管在术后第4天因感染形成血栓。使用单针装置,已进行了693次透析,患者或移植物均出现了一些特殊问题。