Suppr超能文献

使用1平方米和2平方米表面积透析器进行短程透析的两种策略比较。

Comparison of two strategies for short dialysis using 1m2 and 2m2 surface area dialysers.

作者信息

Shaldon S, Florence P, Fontanier P, Polito C, Mion C

出版信息

Proc Eur Dial Transplant Assoc. 1976;12:596-605.

PMID:935141
Abstract

Two matched groups of patients were dialysed either thrice weekly on a double re-used Gambro (2m2) for four and a half hours per dialysis (Group A) or thrice weekly five hours per dialysis on a single non re-used Gambro (1m2) (Group B). There was no significant differences in measured parameters of nitrogen retention between the groups, nor did the mean motor nerve conduction velocity alter significantly in any patient. Both groups preferred short dialysis. No manifestations of inadequate dialysis appeared up to 18 months even in bilateral nephrectomised patients of whom there were 2 in each group. Group B experienced significantly fewer hypovolaemic symptoms during dialysis and the single system in thus preferred. The mean dialysis index in Group A was 1.0 and 0.9 in Group B. These results suggest that a dialysis index of 1.0 overestimates dialysis needs.

摘要

两组匹配的患者进行透析,A组患者每周使用重复使用两次的金宝透析器(2m²)进行三次透析,每次透析4.5小时;B组患者每周使用单次使用的金宝透析器(1m²)进行三次透析,每次透析5小时。两组之间氮潴留的测量参数无显著差异,且任何患者的平均运动神经传导速度均无显著改变。两组患者均倾向于短时间透析。即使在每组各有2例双侧肾切除患者中,长达18个月也未出现透析不充分的表现。B组患者在透析期间出现的血容量不足症状明显较少,因此更倾向于单系统。A组的平均透析指数为1.0,B组为0.9。这些结果表明,透析指数为1.0高估了透析需求。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验