Suppr超能文献

一种新型微需氧系统与其他三种产气系统用于从人类粪便样本中分离弯曲杆菌属细菌的比较。

Comparison of a novel microaerobic system with three other gas-generating systems for the recovery of Campylobacter species from human faecal samples.

作者信息

Bolton F J, Wareing D R, Sails A D

机构信息

The Public Health Laboratory, Royal Preston Hospital, Lancashire, UK.

出版信息

Eur J Clin Microbiol Infect Dis. 1997 Nov;16(11):839-42. doi: 10.1007/BF01700415.

Abstract

Three commercial gas-generating systems--CampyGen (Oxoid, UK), Oxoid BR56 (Oxoid, UK), and CampyPak Plus (Becton Dickinson, USA)--and the evacuation replacement technique were compared for the recovery of Campylobacter spp. from 500 human faecal samples collected from patients with gastroenteritis. Four hundred fifty faecal samples were tested upon receipt in the laboratory. Fifty faecal samples that had been previously found to be positive for Campylobacter spp. were tested retrospectively; these had been stored at 4 degrees C for more than 48 h. A total of 41 (9.1%) of the fresh faecal samples and 41 of 50 (82%) of the stored faecal samples were positive for thermophilic campylobacters. The CampyGen, the Oxoid BR56, the CampyPak Plus, and the evacuation replacement system detected Campylobacter spp. in 40 (97.6%), 39 (95.1%), 41 (100%), and 41 (100%) of the positive fresh faecal samples and in 37 (90.2%), 40 (97.6%), 39 (95.1%), and 40 (97.6%) of the stored samples, respectively. There was no statistical difference in performance of any of the four gas systems used (p = 0.98; chi-square test). Eighty-six percent of the isolates were Campylobacter jejuni and 14% were Campylobacter coli. Biotyping and phage typing of the isolates demonstrated that they were of a diverse range of subtypes. This study demonstrates that thermophilic campylobacters can be isolated from human diarrhoeal faecal samples using any of the four microaerobic-atmosphere-generating systems.

摘要

比较了三种商用产气系统——CampyGen(英国Oxoid公司)、Oxoid BR56(英国Oxoid公司)和CampyPak Plus(美国BD公司)以及抽空置换技术,用于从500份从肠胃炎患者采集的人类粪便样本中分离弯曲杆菌属。450份粪便样本在送达实验室时进行检测。另外回顾性检测了50份先前已检测出弯曲杆菌属呈阳性的粪便样本;这些样本已在4℃保存超过48小时。共有41份(9.1%)新鲜粪便样本和50份中的41份(82%)保存粪便样本嗜热弯曲杆菌呈阳性。CampyGen、Oxoid BR56、CampyPak Plus和抽空置换系统分别在40份(97.6%)、39份(95.1%)、41份(100%)和41份(100%)阳性新鲜粪便样本以及37份(90.2%)、40份(97.6%)、39份(95.1%)和40份(97.6%)保存样本中检测到弯曲杆菌属。所使用的四种气体系统在性能上无统计学差异(p = 0.98;卡方检验)。分离株中86%为空肠弯曲杆菌,14%为结肠弯曲杆菌。对分离株进行生物分型和噬菌体分型表明它们属于多种不同亚型。本研究表明,使用四种微需氧气氛产生系统中的任何一种都可从人类腹泻粪便样本中分离出嗜热弯曲杆菌。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验