• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Assessment of the lactate biosensor methodology.

作者信息

Detry B, Nullens W, Cao M L, Frans A, Robert A, Clerbaux T

机构信息

Cliniques Universitaires Saint-Luc, Université Catholique de Louvain, Brussels, Belgium.

出版信息

Eur Respir J. 1998 Jan;11(1):183-7. doi: 10.1183/09031936.98.11010183.

DOI:10.1183/09031936.98.11010183
PMID:9543291
Abstract

The rapid determination of lactate level is useful for clinical emergencies, as in the case of shock conditions or during surgical operations, as well as in numerous cases of respiratory failure, in cardiac or paediatric pathology and during exercise tests. Moreover, it is of prognostic significance in critically ill patients. Photometric methods are slow and, even when performed in good conditions, will give results only 30 min after blood collection, during which time the clinical condition of the patient may change. In this study, we have assessed the lactate biosensor, a method that yields lactate measurements in less than 1 min with only 100 microL of biological fluid. In order to test the validity of this method, we performed comparisons between the Sigma classical enzymatic reference method and two commercially available biosensors: the Ciba-Corning biosensor 865 and the Yellow Springs lactate biosensor. Lactate measurements were performed in heparinized arterial blood samples without antiglycolitic agent (n=71). In order to cover a wide range of lactate levels, samples came from patients admitted to the intensive care unit for severe conditions and patients addressed for bicycle exercise testing. Each whole blood sample was processed in duplicate by both biosensors. For plasma measurement, subsamples of whole blood were centrifuged and the resulting plasma were processed by the biosensors and the Sigma method. Two parameters that can potentially influence lactate measurement were also investigated: haematocrit and total protein levels. The data showed that measurements performed on plasma are satisfactory for both biosensors. For whole blood, the Ciba-Corning device gives accurate results but the Yellow Springs apparatus seriously underestimates lactate levels. This underestimation is strongly influenced by the haematocrit level, so that a correction factor can be calculated (based on the haemoglobin level), which allows accurate "corrected" results to be obtained for whole blood with the Yellow Springs analyser.

摘要

相似文献

1
Assessment of the lactate biosensor methodology.
Eur Respir J. 1998 Jan;11(1):183-7. doi: 10.1183/09031936.98.11010183.
2
Evaluation of a biosensor for the measurement of lactate in whole blood.用于全血中乳酸测量的生物传感器的评估。
Clin Biochem. 1999 Mar;32(2):109-12. doi: 10.1016/s0009-9120(98)00105-2.
3
[On-site laboratory monitoring on the intensive care unit. Blood gas, electrolyte, glucose, hemoglobin and lactate determination with the CIBA Corning 865 Analysis System].[重症监护病房的现场实验室监测。使用西巴·康宁865分析系统测定血气、电解质、葡萄糖、血红蛋白和乳酸]
Anasthesiol Intensivmed Notfallmed Schmerzther. 1997 Sep;32(9):549-56. doi: 10.1055/s-2007-995109.
4
Technical performance of lactate biosensors and a test-strip device during labour.分娩期间乳酸生物传感器及试纸装置的技术性能
Z Geburtshilfe Neonatol. 2010 Apr;214(2):62-7. doi: 10.1055/s-0030-1249641. Epub 2010 Apr 21.
5
Whole-blood glucose and lactate. Trilayer biosensors, drug interference, metabolism, and practice guidelines.全血葡萄糖和乳酸。三层生物传感器、药物干扰、代谢及实践指南。
Arch Pathol Lab Med. 2000 Aug;124(8):1128-34. doi: 10.5858/2000-124-1128-WBGAL.
6
Evaluation of a lactate sensor for rapid repeated measurements of blood lactate concentration.用于快速重复测量血乳酸浓度的乳酸传感器的评估
Anaesth Intensive Care. 1998 Apr;26(2):184-8. doi: 10.1177/0310057X9802600209.
7
[Evaluation of lactate measurement in blood and plasma with biosensor technology: a comparison of methods].[基于生物传感器技术的血液和血浆中乳酸测量评估:方法比较]
Anaesthesist. 1998 Dec;47(12):968-74. doi: 10.1007/s001010050653.
8
Point-of-care (POC) testing of lactate in the intensive care patient. Accuracy, reliability, and costs of different measurement systems.重症监护患者乳酸的床旁检测。不同测量系统的准确性、可靠性和成本。
Acta Anaesthesiol Scand. 2001 Feb;45(2):194-9. doi: 10.1034/j.1399-6576.2001.450210.x.
9
[The i-STAT analyzer. A new, hand-held device for the bedside determination of hematocrit, blood gases, and electrolytes].[i-STAT分析仪。一种用于床边测定血细胞比容、血气和电解质的新型手持设备]
Anaesthesist. 1997 Aug;46(8):704-14. doi: 10.1007/s001010050457.
10
Lactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.
Clin Chem. 1992 Dec;38(12):2430-4.

引用本文的文献

1
A protein biosensor for lactate.一种用于检测乳酸的蛋白质生物传感器。
Anal Biochem. 2000 Jul 15;283(1):83-8. doi: 10.1006/abio.2000.4611.