Assessment of the lactate biosensor methodology.

作者信息

Detry B, Nullens W, Cao M L, Frans A, Robert A, Clerbaux T

机构信息

Cliniques Universitaires Saint-Luc, Université Catholique de Louvain, Brussels, Belgium.

出版信息

Eur Respir J. 1998 Jan;11(1):183-7. doi: 10.1183/09031936.98.11010183.

Abstract

The rapid determination of lactate level is useful for clinical emergencies, as in the case of shock conditions or during surgical operations, as well as in numerous cases of respiratory failure, in cardiac or paediatric pathology and during exercise tests. Moreover, it is of prognostic significance in critically ill patients. Photometric methods are slow and, even when performed in good conditions, will give results only 30 min after blood collection, during which time the clinical condition of the patient may change. In this study, we have assessed the lactate biosensor, a method that yields lactate measurements in less than 1 min with only 100 microL of biological fluid. In order to test the validity of this method, we performed comparisons between the Sigma classical enzymatic reference method and two commercially available biosensors: the Ciba-Corning biosensor 865 and the Yellow Springs lactate biosensor. Lactate measurements were performed in heparinized arterial blood samples without antiglycolitic agent (n=71). In order to cover a wide range of lactate levels, samples came from patients admitted to the intensive care unit for severe conditions and patients addressed for bicycle exercise testing. Each whole blood sample was processed in duplicate by both biosensors. For plasma measurement, subsamples of whole blood were centrifuged and the resulting plasma were processed by the biosensors and the Sigma method. Two parameters that can potentially influence lactate measurement were also investigated: haematocrit and total protein levels. The data showed that measurements performed on plasma are satisfactory for both biosensors. For whole blood, the Ciba-Corning device gives accurate results but the Yellow Springs apparatus seriously underestimates lactate levels. This underestimation is strongly influenced by the haematocrit level, so that a correction factor can be calculated (based on the haemoglobin level), which allows accurate "corrected" results to be obtained for whole blood with the Yellow Springs analyser.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验