Suppr超能文献

美国国立眼科研究所视觉功能问卷(NEI-VFQ)的心理测量特性。NEI-VFQ现场测试调查人员。

Psychometric properties of the National Eye Institute Visual Function Questionnaire (NEI-VFQ). NEI-VFQ Field Test Investigators.

作者信息

Mangione C M, Lee P P, Pitts J, Gutierrez P, Berry S, Hays R D

机构信息

Department of Medicine, University of California, Los Angeles School of Medicine, USA.

出版信息

Arch Ophthalmol. 1998 Nov;116(11):1496-504. doi: 10.1001/archopht.116.11.1496.

Abstract

OBJECTIVE

To test the reliability and validity of the 51-item Field Test Version of the National Eye Institute Visual Function Questionnaire (NEI-VFQ) across 5 common chronic eye conditions.

DESIGN

Prospective observational cohort study of persons with 1 of 5 chronic eye diseases who were scheduled for nonurgent visits in ophthalmology practices or had low vision from any cause, and a reference sample of persons without eye disease.

SETTING

Six university-based ophthalmology practices and the National Eye Institute Clinical Center, Bethesda, Md.

PATIENTS

Eligible participants had to have 1 of the following eye conditions: age-related cataracts, age-related macular degeneration, diabetic retinopathy, primary open-angle glaucoma, cytomegalovirus retinitis, or low vision from any cause. Each of the 7 sites also enrolled persons in a reference sample. Reference sample participants had no evidence of underlying eye disease but were scheduled for either screening eye examinations or correction of refractive error. All eligible persons had to be aged 21 years or older, English speaking, and cognitively able to give informed consent and participate in a health status interview.

MEASUREMENTS AND MAIN RESULTS

To provide the data needed to assess the reliability and validity of the 51-item NEI-VFQ, all subjects completed an interview that consisted of the 51-item NEI-VFQ, the Medical Outcomes Study 36-Item Short-Form Health Survey, and at least 1 measure of vision-targeted functional status. Estimates of internal consistency and test-retest reproducibility indicate that the 51-item NEI-VFQ is reliable. Tests of association with other scales and clinical variables support the construct validity of the survey.

CONCLUSIONS

In this cross-sectional study, the 51-item NEI-VFQ seems to be reliable and valid and should be a useful tool for group-level comparisons of vision-targeted, health-related quality of life in clinical research. Additionally, the psychometric properties of the NEI-VFQ were not influenced by the type or severity of the underlying eye disease, suggesting that the measure will provide reproducible and valid data when used across multiple eye conditions.

摘要

目的

在5种常见的慢性眼病中测试美国国立眼科研究所视觉功能问卷(NEI-VFQ)51项现场测试版本的可靠性和有效性。

设计

对5种慢性眼病之一的患者进行前瞻性观察队列研究,这些患者计划在眼科诊所进行非紧急就诊或因任何原因导致视力低下,以及一个无眼病的参考样本。

地点

马里兰州贝塞斯达的6家大学眼科诊所和美国国立眼科研究所临床中心。

患者

符合条件的参与者必须患有以下眼病之一:年龄相关性白内障、年龄相关性黄斑变性、糖尿病性视网膜病变、原发性开角型青光眼、巨细胞病毒性视网膜炎或因任何原因导致的视力低下。7个研究地点中的每个地点还招募了参考样本中的人员。参考样本参与者没有潜在眼病的证据,但计划进行眼部筛查或屈光不正矫正。所有符合条件的人员必须年龄在21岁或以上,会说英语,并且在认知上能够给予知情同意并参与健康状况访谈。

测量和主要结果

为了提供评估51项NEI-VFQ可靠性和有效性所需的数据,所有受试者完成了一次访谈,该访谈包括51项NEI-VFQ、医学结局研究36项简短健康调查以及至少1项针对视力的功能状态测量。内部一致性和重测信度的估计表明51项NEI-VFQ是可靠的。与其他量表和临床变量的相关性测试支持了该调查的结构效度。

结论

在这项横断面研究中,51项NEI-VFQ似乎是可靠且有效的,应该是临床研究中针对视力的、与健康相关的生活质量进行组间比较的有用工具。此外,NEI-VFQ的心理测量特性不受潜在眼病类型或严重程度的影响,这表明该测量方法在用于多种眼病时将提供可重复且有效的数据。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验