爱尔兰医院中接受普通诊断性X射线检查患者的参考剂量水平。

Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals.

作者信息

Johnston D A, Brennan P C

机构信息

School of Diagnostic Imaging, University College Dublin, Ireland.

出版信息

Br J Radiol. 2000 Apr;73(868):396-402. doi: 10.1259/bjr.73.868.10844865.

Abstract

Wide variations in patient dose for the same type of X-ray examination have been evident from various international dose surveys. Reference dose levels provide a framework to reduce this variability and aid in the optimization of radiation protection. The aim of this study was to establish, for the first time, a baseline for national reference dose levels in Ireland for four of the most common X-ray examinations: chest, abdomen, pelvis and lumbar spine. Measurements of entrance surface dose using thermoluminescent dosemeters (TLDs) for these four X-ray examinations were performed on 10 patients in each of 16 randomly selected hospitals. This represented 42% of Irish hospitals applicable to this study. Results have shown wide variation of mean hospital doses, from a factor of 3 for an anteroposterior lumbar spine to a factor of 23 for the chest X-ray. The difference between maximum and minimum individual patient dose values varied up to a factor of 75. Reasons for these dose variations were complex but, in general, low tube potential, high mAs and low filtration were associated with high-dose hospitals. This study also demonstrated lower reference dose levels of up to 40% when compared with those established by the UK and the Commission of the European Communities for four out of six projections. Only the chest X-ray exhibited a similar reference level to those established elsewhere. This emphasizes the importance of each country establishing its own reference dose levels that are appropriate to their own radiographic techniques and practices in order to optimize patient protection.

摘要

各种国际剂量调查表明,相同类型的X射线检查中患者剂量存在很大差异。参考剂量水平为减少这种变异性并有助于优化辐射防护提供了一个框架。本研究的目的是首次为爱尔兰四种最常见的X射线检查(胸部、腹部、骨盆和腰椎)建立国家参考剂量水平的基线。在随机选择的16家医院中,对每家医院的10名患者进行了这四种X射线检查的入射表面剂量测量,使用热释光剂量计(TLD)。这占适用于本研究的爱尔兰医院的42%。结果显示,平均医院剂量差异很大,前后位腰椎的差异系数为3,胸部X射线的差异系数为23。最大和最小个体患者剂量值之间的差异高达75倍。这些剂量差异的原因很复杂,但一般来说,低管电压、高毫安秒和低过滤与高剂量医院有关。与英国和欧洲共同体委员会确定的参考剂量水平相比,本研究还表明,在六个投影中的四个投影中,参考剂量水平低达40%。只有胸部X射线的参考水平与其他地方确定的水平相似。这强调了每个国家建立适合其自身放射技术和实践的参考剂量水平对于优化患者防护的重要性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验