使用VOCAL成像程序获取和测量子宫内膜体积的可重复性。

The reproducibility of endometrial volume acquisition and measurement with the VOCAL-imaging program.

作者信息

Raine-Fenning N, Campbell B, Collier J, Brincat M, Johnson I

机构信息

School of Human Development, Academic Division of Reproductive Medicine, Queens Medical Centre, Nottingham, UK.

出版信息

Ultrasound Obstet Gynecol. 2002 Jan;19(1):69-75. doi: 10.1046/j.0960-7692.2001.00608.x.

Abstract

OBJECTIVES

To determine the intraobserver reproducibility of volume acquisition and repeatability of endometrial volume measurements using the VOCAL-imaging program (Virtual Organ Computer-aided AnaLysis).

METHODS

Ten three-dimensional (3D) ultrasound datasets of the same endometrium were obtained from one patient during one scan session. For every 3D dataset, the endometrial volume was calculated by four different measurement techniques; three rotational methods and one conventional method. A single observer acquired each dataset and conducted all measurements. For the rotational technique, the manual mode was used to trace the myometrial-endometrial border through three different predefined rotations of 30 degrees, 15 degrees and 9 degrees . Endometrial volume was also measured in a conventional manner by scrolling through one of the multiplanar images and outlining the contour in another. Ten consecutive measurements were taken for each of the four measurement techniques so that 40 endometrial volume readings were obtained for each of the 10 3D-ultrasound datasets.

RESULTS

Endometrial volume measurements were more reproducible with the rotational technique. Rotational methods employing a rotation step of less than 30 degrees were associated with coefficients of variation below 1% and intraclass correlation coefficients above 0.94. Within each of the 10 different scans, the homogeneity of the variance of measurements was significantly different according to the method of measurement (P = 0.022 to < 0.001). Post-hoc tests revealed that both the conventional and 30 degrees rotational methods resulted in a significantly smaller mean endometrial volume than both the 15 degrees and the 9 degrees rotational methods.

CONCLUSIONS

Endometrial volume acquisition is reproducible and endometrial volume measurements are repeatable but they depend upon the technique of volume calculation in so much as rotational methods employing a rotation step of less than 30 degrees are associated with a significantly smaller variance in measurements and a significantly greater mean endometrial volume.

摘要

目的

使用VOCAL成像程序(虚拟器官计算机辅助分析)确定容积采集的观察者内可重复性以及子宫内膜容积测量的可重复性。

方法

在一次扫描过程中从一名患者获取10个相同子宫内膜的三维(3D)超声数据集。对于每个3D数据集,通过四种不同的测量技术计算子宫内膜容积;三种旋转方法和一种传统方法。由一名观察者获取每个数据集并进行所有测量。对于旋转技术,使用手动模式通过30度、15度和9度三种不同的预定义旋转来追踪肌层-内膜边界。子宫内膜容积也通过滚动多平面图像之一并在另一个图像中勾勒轮廓的传统方式进行测量。对四种测量技术中的每一种进行连续十次测量,以便为10个3D超声数据集中的每一个获得40个子宫内膜容积读数。

结果

旋转技术测量的子宫内膜容积更具可重复性。采用小于30度旋转步长的旋转方法变异系数低于1%,组内相关系数高于0.94。在10次不同扫描中的每一次内,测量方差的同质性根据测量方法有显著差异(P = 0.022至<0.001)。事后检验显示,传统方法和30度旋转方法得出的平均子宫内膜容积均显著小于15度和9度旋转方法。

结论

子宫内膜容积采集具有可重复性,子宫内膜容积测量具有可重复性,但它们取决于容积计算技术,因为采用小于30度旋转步长的旋转方法测量方差显著更小,平均子宫内膜容积显著更大。