Suppr超能文献

髓腔刚度对根管治疗后冠修复牙体外骨折的影响。

Effect of core stiffness on the in vitro fracture of crowned, endodontically treated teeth.

作者信息

Pilo Raphael, Cardash Harold S, Levin Eli, Assif David

机构信息

Department of Prosthetic Dentistry, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.

出版信息

J Prosthet Dent. 2002 Sep;88(3):302-6. doi: 10.1067/mpr.2002.127909.

Abstract

STATEMENT OF PROBLEM

Dentin and core materials that substitute for missing dentin are dissimilar materials. A core material with a lower elastic modulus may deform more under applied stress and therefore result in reduced stress concentration at the core/dentin junction.

PURPOSE

This in vitro study examined the effect of core stiffness on the fracture resistance and failure characteristics of a crowned, endodontically treated tooth under simulated occlusal load.

MATERIAL AND METHODS

Forty extracted human mandibular premolars were divided equally into 4 groups and prepared for posts and cast crowns as follows: group 1 = cast post and core, cast crown; group 2 = preformed metal post, composite core, and cast crown; group 3 = preformed metal post, amalgam core, and cast crown; and group 4 (control) = preformed metal post, no core, and cast crown. All prepared teeth had 2 mm of sound dentin on which the cemented crown rested. A continuous load (kg) was applied to the buccal cusp at a 30-degree angle to the long axis of each tooth at a crosshead speed of 2 mm/min until failure. Collected data were subjected to 1-way analysis of variance with the Welch modification to compare groups (P<.05).

RESULTS

Failure loads for the 4 test groups were as follows: 98.1 +/- 34.6 kg (group 1), 94.4 +/- 41.8 kg (group 2), 105.5 +/- 18.6 kg (group 3), and 101.1 +/- 55.3 kg (group 4). No significant difference in failure load values was found among the 4 groups. The primary mode of failure (80%) in all groups was an oblique radicular fracture, either apical to the post or at the post level. Horizontal fracture of the root and post was found in groups 1, 2, and 3 (20%). Loosening of the crown, post, and core was found only in group 2(20%).

CONCLUSION

Within the limitations of this study, core stiffness did not affect the failure resistance of teeth restored with posts and cores and complete-coverage cast metal crowns. The dominant pattern of failure was unrepairable root fracture. Only the composite core exhibited repairable fractures.

摘要

问题陈述

牙本质和替代缺失牙本质的核材料是不同的材料。弹性模量较低的核材料在施加应力下可能变形更大,因此会导致核/牙本质交界处的应力集中降低。

目的

本体外研究在模拟咬合负荷下,检测核刚度对根管治疗后戴冠牙齿的抗折性及失效特征的影响。

材料与方法

40颗拔除的人下颌前磨牙平均分为4组,并按如下方法预备桩和铸造冠:第1组=铸造桩核、铸造冠;第2组=预成金属桩、复合树脂核、铸造冠;第3组=预成金属桩、银汞合金核、铸造冠;第4组(对照组)=预成金属桩、无核、铸造冠。所有预备好的牙齿均有2mm健康牙本质供粘结冠就位。以2mm/min的十字头速度,在与每颗牙齿长轴呈30度角的颊尖施加连续负荷(kg)直至牙齿折断。收集的数据采用经韦尔奇校正的单因素方差分析进行组间比较(P<0.05)。

结果

4个试验组的折断负荷如下:98.1±34.6kg(第1组),94.4±41.8kg(第2组),105.5±18.6kg(第3组),101.1±55.3kg(第4组)。4组间折断负荷值无显著差异。所有组的主要折断模式(80%)为斜行根折,位于桩尖部或桩水平处。第1、2和3组出现牙根和桩的水平折断(20%)。仅在第2组发现冠、桩和核松动(20%)。

结论

在本研究的局限性范围内,核刚度不影响用桩核及全冠修复牙齿的抗折性。主要的折断模式是不可修复的根折。只有复合树脂核表现出可修复的折断。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验