The antimicrobial susceptibilities of 100 clinical isolates of Pseudomonas aeruginosa to gentamicin, amikacin, tobramycin, ticarcillin, piperacillin, and ceftazidime were determined by using the Sceptor system (BBL Microbiology Systems, Cockeysville, Md.), and the results were compared with those obtained using the National Committee for Clinical Laboratory Standards reference agar dilution method. Excellent correlation was observed for the aminoglycosides, with greater than 95% agreement within 1 doubling dilution of the reference agar dilution MIC, while ticarcillin and piperacillin showed lower percent agreement values of 91 and 88%, respectively.

摘要

采用Sceptor系统(BBL微生物系统公司,马里兰州科基斯维尔)测定了100株临床分离的铜绿假单胞菌对庆大霉素、阿米卡星、妥布霉素、替卡西林、哌拉西林和头孢他啶的抗菌敏感性,并将结果与使用美国国家临床实验室标准委员会参考琼脂稀释法获得的结果进行比较。观察到氨基糖苷类药物具有良好的相关性,在参考琼脂稀释法最低抑菌浓度(MIC)的1倍稀释范围内,一致性大于95%,而替卡西林和哌拉西林的一致性百分比分别较低,为91%和88%。