Suppr超能文献

Comparison between the enzymatic vitros assay for creatinine determination and three other methods adapted on the Olympus analyzer.

作者信息

Badiou S, Dupuy A M, Descomps B, Cristolead J P

机构信息

Laboratoire de Biochimie, Hopital Lapeyronie, Montpellier, France.

出版信息

J Clin Lab Anal. 2003;17(6):235-40. doi: 10.1002/jcla.10103.

Abstract

To evaluate the relationship between the enzymatic Vitros assay for creatinine determination and other methods, we determined creatinine concentration in 400 heparin samples. Plasma creatinine level was successively determined on the Vitros 750 analyzer (Johnson & Johnson Co., Rochester, NY) and on the Olympus AU2700 analyzer (Olympus France, Rungis, France), using three reagents in the same assay: Olympus-Jaffé and two enzymatic commercial kits-Crea Plus (Roche Diagnostics, Meylan, France) and Enzymatic Creatinine (Randox, Mauguio, France). Comparison of Jaffé and enzymatic measurements of plasma creatinine levels revealed a high correlation when considering all values ranged from 20-1000 micromol/l (r > 0.99). However, for values <60 micromol/l, enzymatic reagents provided best results. Enzymatic methodology is a better clinical choice for the accurate measurement of creatinine, especially for neonates, pediatrics, and hematology units. Because analytical performance and the costs of Randox creatinine were satisfactory for our laboratory, this method, adapted on the Olympus analyzer, was chosen for routine determination of creatinine levels. According to the Valtec protocol (8), no interferences such as hemolysis, lipemia, or bilirubin were detected for Enzymatic Creatinine Randox.

摘要

相似文献

2
Adaptation and evaluation of the Randox full-range CRP assay on the Olympus AU2700.
J Clin Lab Anal. 2007;21(1):34-9. doi: 10.1002/jcla.20160.
3
Inaccuracy of routine creatinine measurement in canine urine.
Vet Clin Pathol. 2004;33(3):128-32. doi: 10.1111/j.1939-165x.2004.tb00361.x.
5
Creatinine concentration in plasma from dog, rat, and mouse: a comparison of 3 different methods.
Vet Clin Pathol. 2005 Sep;34(3):232-6. doi: 10.1111/j.1939-165x.2005.tb00046.x.
9
Clinical and Analytical Impact of Moving from Jaffe to Enzymatic Serum Creatinine Methodology.
J Appl Lab Med. 2020 Jul 1;5(4):631-642. doi: 10.1093/jalm/jfaa053.

引用本文的文献

1
Shedding light on the shadows: oxidative stress and its pivotal role in prostate cancer progression.
Front Oncol. 2024 May 7;14:1393078. doi: 10.3389/fonc.2024.1393078. eCollection 2024.
2
Neutrophil extracellular traps in urinary tract infection.
Front Pediatr. 2023 Mar 20;11:1154139. doi: 10.3389/fped.2023.1154139. eCollection 2023.
3
Oxidative Stress Markers in Urine and Serum of Patients with Bladder Cancer.
Antioxidants (Basel). 2023 Jan 26;12(2):277. doi: 10.3390/antiox12020277.
4
Extracellular DNA concentrations in various aetiologies of acute kidney injury.
Sci Rep. 2022 Oct 7;12(1):16812. doi: 10.1038/s41598-022-21248-7.
5
Analytical performance evaluation of different test systems on serum creatinine assay.
J Clin Lab Anal. 2022 Feb;36(2):e24206. doi: 10.1002/jcla.24206. Epub 2021 Dec 26.
6
Hepatorenal syndrome in acute-on-chronic liver failure with acute kidney injury: more questions requiring discussion.
Gastroenterol Rep (Oxf). 2021 Sep 25;9(6):505-520. doi: 10.1093/gastro/goab040. eCollection 2021 Dec.
9
How to estimate renal function in patients with liver disease: choosing the most suitable equation.
Int Urol Nephrol. 2019 Apr;51(4):677-690. doi: 10.1007/s11255-019-02110-8. Epub 2019 Mar 4.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验