Packer Mark, Fine I Howard, Hoffman Richard S, Piers Patricia A
Oregon Eye Institute, Eugene 97401, USA.
J Cataract Refract Surg. 2004 May;30(5):986-92. doi: 10.1016/j.jcrs.2003.10.022.
To evaluate whether the Tecnis Z9000 intraocular lens (IOL) (Pfizer) with a modified prolate anterior surface provides better quality of vision than a conventional spherical IOL.
Oregon Eye Institute, Eugene, Oregon, USA.
Patients presenting for cataract surgery who were randomly assigned to receive a Tecnis Z9000 IOL (Pfizer) or a Sensar OptiEdge AR40e IOL (AMO) in 1 eye were followed for 3 months postoperatively. The patient could elect to have the same type of IOL implanted in the fellow eye. The results of sine-wave grating contrast sensitivity testing under mesopic and photopic conditions were compared interindividually.
Monocular comparison was made between the 2 IOL groups, which comprised 15 patients each. The Tecnis IOL provided significantly better contrast sensitivity at 6 cycles per degree (cpd) under photopic conditions and at 1.5 and 3 cpd under mesopic conditions. Seven patients with a Tecnis IOL and 9 patients with an AR40e IOL had subsequent implantation in the fellow eye. In all eyes, including fellow eyes, having IOL implantation, the Tecnis provided significantly better contrast sensitivity at 3 and 6 cpd under photopic conditions and at 1.5, 3, and 6 cpd under mesopic conditions. The mean contrast sensitivity in fellow eyes showed that the Tecnis IOL produced significantly better results at some spatial frequencies.
Results show the Tecnis IOL with a modified prolate anterior surface may produce better contrast sensitivity than a standard spherical IOL under mesopic and photopic conditions. Because contrast sensitivity testing correlates well with functional vision, a goal of future research should be to evaluate patient performance using functional tests such as driving simulation.
评估具有改良长椭圆形前表面的Tecnis Z9000人工晶状体(IOL)(辉瑞公司)是否比传统的球面IOL提供更好的视觉质量。
美国俄勒冈州尤金市的俄勒冈眼科研究所。
将接受白内障手术的患者随机分配,一只眼植入Tecnis Z9000 IOL(辉瑞公司)或Sensar OptiEdge AR40e IOL(AMO公司),术后随访3个月。患者可选择在另一只眼中植入相同类型的IOL。对个体间在中间视觉和明视觉条件下的正弦波光栅对比敏感度测试结果进行比较。
对两个IOL组进行单眼比较,每组各有15名患者。Tecnis IOL在明视觉条件下每度6周/度(cpd)以及中间视觉条件下1.5和3 cpd时提供了显著更好的对比敏感度。7名植入Tecnis IOL的患者和9名植入AR40e IOL的患者随后在另一只眼中植入了IOL。在所有植入IOL的眼中,包括另一只眼,Tecnis在明视觉条件下3和6 cpd以及中间视觉条件下1.5、3和6 cpd时提供了显著更好的对比敏感度。另一只眼中的平均对比敏感度表明,Tecnis IOL在某些空间频率下产生了显著更好的结果。
结果表明,具有改良长椭圆形前表面的Tecnis IOL在中间视觉和明视觉条件下可能比标准球面IOL产生更好的对比敏感度。由于对比敏感度测试与功能性视力密切相关,未来研究的一个目标应该是使用驾驶模拟等功能测试来评估患者的表现。