A broad variety of bacterial strains, including 79 Pseudomonas aeruginosa, were studied in an in vitro evaluation of carbenicillin disk susceptibility testing. Regression analysis with both 50-mug and 100-mug carbenicillin disks was carried out. Organisms having minimal inhibitory concentration values of 100 to 200 mug/ml demonstrated zones of less than 11 mm with the 50-mug disk, resulting in very little opportunity for appropriate discrimination of results. The line of regression for the 50-mug disk intersected the ordinate at a point just above the minimal inhibitory concentration value considered to be the limit of intermediate susceptibility for Pseudomonas. These considerations, together with evidence of greater disk content variation in the 50-mug than in the 100-mug disks assayed, considerable manufacturer-to-manufacturer variability with the 50-mug disk, and the more appropriate performance of the 100-mug disk, lead us to conclude that the 100-mug disk better serves the clinical test requirements for this agent than does the 50-mug disk, which is currently the only disk available for laboratory testing.
在羧苄青霉素纸片药敏试验的体外评估中,研究了包括79株铜绿假单胞菌在内的多种细菌菌株。对含50微克和100微克羧苄青霉素的纸片进行了回归分析。最低抑菌浓度值为100至200微克/毫升的菌株,使用50微克纸片时抑菌圈小于11毫米,导致正确区分结果的机会很少。50微克纸片的回归线在纵坐标上的交点略高于被认为是铜绿假单胞菌中度敏感极限的最低抑菌浓度值。这些因素,再加上检测的50微克纸片比100微克纸片的含量变异更大、不同厂家生产的50微克纸片存在相当大的差异以及100微克纸片表现更合适,使我们得出结论,与50微克纸片相比,100微克纸片更能满足该药物的临床检测要求,而50微克纸片是目前实验室检测中唯一可用的纸片。