Abstract

PURPOSE

The usefulness of diffusion-weighted imaging (DWI) in the field of neuroradiology has been established. Despite its high contrast resolution, DWI has the disadvantages of susceptibility artifact and chemical shift artifact. We performed DWI of breast cancer with the sensitivity encoding (SENSE) technique.

METHODS

The subjects were 60 female patients with breast mass. All patients underwent MRI including SENSE-DWI and were diagnosed histologically. Of these patients, 55 were diagnosed with breast cancer and the remaining five were diagnosed with benign mass. The histological diagnoses of breast cancer were as follows: 39 cases of invasive ductal carcinoma (IDC); 11 cases of IDC with a predominant intraductal component and non IDC (pure or predominant NIDC); and five cases of special types of cancer. The MR system used was a Gyroscan Intera 1.5T (Philips Medical Systems). In addition to routine MRI for breast cancer, including contrast-enhanced dynamic, SENSE-DWI was obtained. The accuracy of the positional information of SENSE-DWI was visually compared with that of conventional images. The apparent diffusion coefficient (ADC) values of breast mass were analyzed with SENSE-DWI.

RESULTS

The accuracy of positional information was adequate for diagnosing of all patients. The mean ADC value of breast cancer was 1.021x10(-3) mm2/s and that of benign mass was 1.488x10(-3) mm2/s (p=0.0002). The mean ADC value of IDC was 0.968x10(-3) mm2/s and that of pure or predominant NIDC was 1.218x10(-3) mm2/s (p=0.0011).

CONCLUSION

SENSE-DWI was of sufficient quality to support diagnosis of breast mass. SENSE-DWI may permit the acquisition of more detailed information about lesions, including tumor cellularity, that is difficult to obtain with conventional techniques.

摘要

目的

扩散加权成像(DWI)在神经放射学领域的实用性已得到确立。尽管DWI具有高对比分辨率,但存在敏感性伪影和化学位移伪影的缺点。我们采用敏感性编码(SENSE)技术对乳腺癌进行了DWI检查。

方法

研究对象为60例有乳腺肿块的女性患者。所有患者均接受了包括SENSE-DWI在内的MRI检查,并进行了组织学诊断。其中55例被诊断为乳腺癌,其余5例被诊断为良性肿块。乳腺癌的组织学诊断如下:浸润性导管癌(IDC)39例;导管内成分占优势的IDC和非IDC(纯或主要为非IDC)11例;特殊类型癌5例。使用的MR系统为Gyroscan Intera 1.5T(飞利浦医疗系统公司)。除了用于乳腺癌的常规MRI检查,包括对比增强动态成像外,还进行了SENSE-DWI检查。将SENSE-DWI的位置信息准确性与传统图像进行视觉比较。用SENSE-DWI分析乳腺肿块的表观扩散系数(ADC)值。

结果

位置信息的准确性足以对所有患者进行诊断。乳腺癌的平均ADC值为1.021×10⁻³mm²/s,良性肿块的平均ADC值为1.488×10⁻³mm²/s(p = 0.0002)。IDC的平均ADC值为0.968×10⁻³mm²/s,纯或主要为非IDC的平均ADC值为1.218×10⁻³mm²/s(p = 0.0011)。

结论

SENSE-DWI质量足以支持乳腺肿块的诊断。SENSE-DWI可能有助于获取有关病变的更详细信息,包括肿瘤细胞密度,而这些信息用传统技术难以获得。