Institute for Applied Microbiology, University of Tennessee, Knoxville, Tennessee 37932-2567, and Environmental Sciences Division, Oak Ridge National Laboratory, P. O. Box 2008, Oak Ridge, Tennessee 37831-6038.
Appl Environ Microbiol. 1990 Jun;56(6):1702-9. doi: 10.1128/aem.56.6.1702-1709.1990.
Experimental bioreactors operated as recirculated closed systems were inoculated with bacterial cultures that utilized methane, propane, and tryptone-yeast extract as aerobic carbon and energy sources and degraded trichloroethylene (TCE). Up to 95% removal of TCE was observed after 5 days of incubation. Uninoculated bioreactors inhibited with 0.5% Formalin and 0.2% sodium azide retained greater than 95% of their TCE after 20 days. Each bioreactor consisted of an expanded-bed column through which the liquid phase was recirculated and a gas recharge column which allowed direct headspace sampling. Pulses of TCE (20 mg/liter) were added to bioreactors, and gas chromatography was used to monitor TCE, propane, methane, and carbon dioxide. Pulsed feeding of methane and propane with air resulted in 1 mol of TCE degraded per 55 mol of substrate utilized. Perturbation studies revealed that pH shifts from 7.2 to 7.5 decreased TCE degradation by 85%. The bioreactors recovered to baseline activities within 1 day after the pH returned to neutrality.
采用循环闭路系统的实验生物反应器接种了利用甲烷、丙烷和胰蛋白胨-酵母提取物作为需氧碳源和能源的细菌培养物,可降解三氯乙烯 (TCE)。经过 5 天的孵育,观察到 TCE 的去除率高达 95%。用 0.5%甲醛和 0.2%叠氮化钠抑制的未接种生物反应器在 20 天后仍保留了超过 95%的 TCE。每个生物反应器由一个扩展床柱组成,液相在其中循环,一个气体补充柱允许直接进行顶部空间采样。将 TCE(20mg/L)脉冲添加到生物反应器中,并用气相色谱法监测 TCE、丙烷、甲烷和二氧化碳。用空气脉冲进料甲烷和丙烷导致每消耗 55 摩尔底物就降解 1 摩尔 TCE。扰动研究表明,pH 值从 7.2 降至 7.5 会使 TCE 降解减少 85%。在 pH 值恢复中性后,生物反应器在 1 天内恢复到基线活性。