Suppr超能文献

Lenstec KH-3500“调节性”人工晶状体的主观和客观性能

Subjective and objective performance of the Lenstec KH-3500 "accommodative" intraocular lens.

作者信息

Wolffsohn J S, Naroo S A, Motwani N K, Shah S, Hunt O A, Mantry S, Sira M, Cunliffe I A, Benson M T

机构信息

School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham, UK.

出版信息

Br J Ophthalmol. 2006 Jun;90(6):693-6. doi: 10.1136/bjo.2006.090951. Epub 2006 Mar 10.

Abstract

AIM

To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs.

METHODS

28 participants were implanted monocularly with a KH-3500 "accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at approximately 3 weeks and repeated after 6 months.

RESULTS

Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) microm and lower order were 0.24 (0.39) microm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05).

CONCLUSIONS

The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.

摘要

目的

确定与标准单焦点人工晶状体相比,植入Lenstec KH - 3500“可调节”人工晶状体(IOL)的眼睛在主观和客观聚焦性能方面是否有所改善。

方法

28名参与者单眼植入KH - 3500“可调节”IOL,20名对照者植入Softec1 IOL。在大约3周时进行屈光、视力、主观调节幅度、客观调节刺激反应曲线、像差测量和Scheimpflug成像等结果测量,并在6个月后重复进行。

结果

KH - 3500的最佳矫正视力在远距为0.06(标准差0.13)logMAR,在近距为0.58(0.20)logMAR。客观测量的调节力为0.39(0.53)D,主观测量为3.1(1.6)D。高阶像差为0.87(0.85)微米,低阶像差为0.24(0.39)微米。后囊下光散射比IOL清晰度高0.95%(1.37%)。相比之下,除了客观(0.17(0.13)D;p = 0.032)和主观(2.0(0.9)D;p = 0.009)调节幅度外,所有对照组测量结果相似。手术后6个月,植入KH - 3500的受试者后囊下散射增加(p<0.01),近距文字视力下降(p<0.05)。

结论

KH - 3500 IOL的客观调节效果似乎有限,尽管与植入传统IOL的对照受试者相比,主观和客观调节范围显著增加。然而,这种晶状体的“调节”能力在手术后6个月似乎有所下降。

相似文献

1
Subjective and objective performance of the Lenstec KH-3500 "accommodative" intraocular lens.
Br J Ophthalmol. 2006 Jun;90(6):693-6. doi: 10.1136/bjo.2006.090951. Epub 2006 Mar 10.
2
Objective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens.
Invest Ophthalmol Vis Sci. 2006 Mar;47(3):1230-5. doi: 10.1167/iovs.05-0939.
3
Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.
J Cataract Refract Surg. 2007 Jan;33(1):47-52. doi: 10.1016/j.jcrs.2006.08.049.
5
A randomized intraindividual comparison of the accommodative performance of the bag-in-the-lens intraocular lens in presbyopic eyes.
Am J Ophthalmol. 2010 Nov;150(5):619-627.e1. doi: 10.1016/j.ajo.2010.06.003. Epub 2010 Aug 16.
6
Visual and accommodative outcomes 1 year after implantation of an accommodating intraocular lens based on a new concept.
J Cataract Refract Surg. 2009 Oct;35(10):1671-8. doi: 10.1016/j.jcrs.2009.04.043.
8
Longterm results of 1 CU accommodative intraocular lens implantation: 2-year follow-up study.
Acta Ophthalmol Scand. 2007 Jun;85(4):409-14. doi: 10.1111/j.1600-0420.2006.00866.x. Epub 2007 Apr 2.
9
Visual outcomes after accommodating intraocular lens implantation.
J Cataract Refract Surg. 2006 Apr;32(4):628-33. doi: 10.1016/j.jcrs.2006.01.027.

引用本文的文献

2
New insights in presbyopia: impact of correction strategies.
BMJ Open Ophthalmol. 2023 Jan;8(1). doi: 10.1136/bmjophth-2022-001122.
6
Clinical application of accommodating intraocular lens.
Int J Ophthalmol. 2018 Jun 18;11(6):1028-1037. doi: 10.18240/ijo.2018.06.22. eCollection 2018.
7
Cyclodextrin-containing hydrogels as an intraocular lens for sustained drug release.
PLoS One. 2017 Dec 15;12(12):e0189778. doi: 10.1371/journal.pone.0189778. eCollection 2017.
8
Visual performance with accommodating and multifocal intraocular lenses.
Int J Ophthalmol. 2017 Feb 18;10(2):235-240. doi: 10.18240/ijo.2017.02.09. eCollection 2017.
10
Age-related changes in the anterior segment biometry during accommodation.
Invest Ophthalmol Vis Sci. 2015 Jun;56(6):3522-30. doi: 10.1167/iovs.15-16825.

本文引用的文献

1
Stimulus-driven versus pilocarpine-induced biometric changes in pseudophakic eyes.
Ophthalmology. 2005 Mar;112(3):453-9. doi: 10.1016/j.ophtha.2004.09.021.
4
Clinical study of the 1CU accommodating intraocular lens.
J Cataract Refract Surg. 2003 Jul;29(7):1307-12. doi: 10.1016/s0886-3350(03)00072-5.
5
Distance and near contrast sensitivity function after multifocal intraocular lens implantation.
J Cataract Refract Surg. 2003 Apr;29(4):703-11. doi: 10.1016/s0886-3350(02)01648-6.
6
Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens.
J Cataract Refract Surg. 2003 Apr;29(4):677-85. doi: 10.1016/s0886-3350(02)01893-x.
7
Intraocular lens movement caused by ciliary muscle contraction.
J Cataract Refract Surg. 2003 Apr;29(4):669-76. doi: 10.1016/s0886-3350(02)01652-8.
8
Cardinal points and image-object magnification with an accommodative lens implant (1 CU).
Ophthalmic Physiol Opt. 2003 Jan;23(1):61-70. doi: 10.1046/j.1475-1313.2003.00090.x.
10
[Miyake-Apple video analysis of movement patterns of an accommodative intraocular lens implant].
Ophthalmologe. 2002 Nov;99(11):811-4. doi: 10.1007/s00347-002-0717-7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验