Wolffsohn J S, Naroo S A, Motwani N K, Shah S, Hunt O A, Mantry S, Sira M, Cunliffe I A, Benson M T
School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham, UK.
Br J Ophthalmol. 2006 Jun;90(6):693-6. doi: 10.1136/bjo.2006.090951. Epub 2006 Mar 10.
To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs.
28 participants were implanted monocularly with a KH-3500 "accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at approximately 3 weeks and repeated after 6 months.
Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) microm and lower order were 0.24 (0.39) microm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05).
The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.
确定与标准单焦点人工晶状体相比,植入Lenstec KH - 3500“可调节”人工晶状体(IOL)的眼睛在主观和客观聚焦性能方面是否有所改善。
28名参与者单眼植入KH - 3500“可调节”IOL,20名对照者植入Softec1 IOL。在大约3周时进行屈光、视力、主观调节幅度、客观调节刺激反应曲线、像差测量和Scheimpflug成像等结果测量,并在6个月后重复进行。
KH - 3500的最佳矫正视力在远距为0.06(标准差0.13)logMAR,在近距为0.58(0.20)logMAR。客观测量的调节力为0.39(0.53)D,主观测量为3.1(1.6)D。高阶像差为0.87(0.85)微米,低阶像差为0.24(0.39)微米。后囊下光散射比IOL清晰度高0.95%(1.37%)。相比之下,除了客观(0.17(0.13)D;p = 0.032)和主观(2.0(0.9)D;p = 0.009)调节幅度外,所有对照组测量结果相似。手术后6个月,植入KH - 3500的受试者后囊下散射增加(p<0.01),近距文字视力下降(p<0.05)。
KH - 3500 IOL的客观调节效果似乎有限,尽管与植入传统IOL的对照受试者相比,主观和客观调节范围显著增加。然而,这种晶状体的“调节”能力在手术后6个月似乎有所下降。