The multiple inert gas elimination technique (MIGET) represents the gold standard for analysis of ventilation and perfusion distributions in the lung. Modification of this technique allows a much simpler sample processing and hence permits routine clinical application of this technique. MIGET using micropore membrane inlet mass spectrometry (MMIMS) might, therefore, facilitate early diagnosis of lung diseases and monitoring of therapeutic interventions in the future.
多惰性气体排除技术(MIGET)是分析肺通气和灌注分布的金标准。对该技术的改进使得样本处理更加简单,从而使该技术能够在临床常规应用。因此,使用微孔膜进样质谱法(MMIMS)的MIGET可能会在未来促进肺部疾病的早期诊断和治疗干预的监测。