使用海德堡视网膜断层扫描仪评估不同类型视神经病变中的视盘形态。

Evaluation of optic nerve head configuration in various types of optic neuropathy with Heidelberg Retina Tomograph.

作者信息

Nagai-Kusuhara A, Nakamura M, Kanamori A, Nakanishi Y, Kusuhara S, Negi Akira

机构信息

Division of Ophthalmology, Department of Organs Therapeutics, Kobe University Graduate School of Medicine, Chuo-ku, Kobe, Japan.

出版信息

Eye (Lond). 2008 Sep;22(9):1154-60. doi: 10.1038/sj.eye.6702871. Epub 2007 May 25.

Abstract

PURPOSE

To test whether Heidelberg Retina Tomograph (HRT) is applicable to assess the optic nerve head (ONH) configuration of the atrophic phase of non-glaucomatous optic neuropathy when a default set of the reference plane is used.

METHODS

Ten eyes with non-arteritic anterior ischaemic optic neuropathy (NAION), 17 eyes with Leber's hereditary optic neuropathy (LHON), 40 eyes with compressive optic neuropathy (CON) owing to chiasmal tumour, and 241 eyes of control individuals were examined with HRT using the default reference plane. The global values of HRT parameters were evaluated among the groups of patients and controls. The sectoral measurements of the eyes with LHON and CON were compared with controls. To eliminate the influence of disc size and age on HRT measurements, eyes with disc area- and age-matched normal controls were used for comparison with eyes with NAION and LHON.

RESULTS

Cup parameters in eyes with NAION were similar to those in controls. The retinal nerve fibre layer (RNFL) thickness was significantly thinner in eyes with NAION than that of controls. The eyes with LHON had significantly larger cup parameters, smaller rim volume, and thinner mean RNFL thickness than controls. Eyes with CON had significantly larger rim area and smaller cup parameters but similar RNFL thickness compared with controls.

CONCLUSIONS

When the default reference plane is used, HRT can measure the ONH configuration in eyes with NAION and LHON as expected. However, caution must be made to interpret the parameters obtained from the eyes with CON.

摘要

目的

当使用默认的参考平面设置时,测试海德堡视网膜断层扫描仪(HRT)是否适用于评估非青光眼性视神经病变萎缩期的视神经乳头(ONH)形态。

方法

使用默认参考平面,对10例非动脉炎性前部缺血性视神经病变(NAION)患者的眼睛、17例Leber遗传性视神经病变(LHON)患者的眼睛、40例因视交叉肿瘤导致的压迫性视神经病变(CON)患者的眼睛以及241例对照个体的眼睛进行HRT检查。评估患者组和对照组之间HRT参数的整体值。将LHON和CON患者眼睛的扇形测量结果与对照组进行比较。为消除视盘大小和年龄对HRT测量的影响,使用视盘面积和年龄匹配的正常对照眼睛与NAION和LHON患者的眼睛进行比较。

结果

NAION患者眼睛的杯状参数与对照组相似。NAION患者眼睛的视网膜神经纤维层(RNFL)厚度明显薄于对照组。LHON患者的眼睛杯状参数明显更大,边缘体积更小,平均RNFL厚度比对照组更薄。与对照组相比,CON患者的眼睛边缘面积明显更大,杯状参数更小,但RNFL厚度相似。

结论

当使用默认参考平面时,HRT可以如预期那样测量NAION和LHON患者眼睛的ONH形态。然而,对于从CON患者眼睛获得的参数解释必须谨慎。