White R L, Kays M B, Friedrich L V, Brown E W, Koonce J R
College of Pharmacy, Medical University of South Carolina, Charleston 29425-0810.
J Clin Microbiol. 1991 Feb;29(2):398-400. doi: 10.1128/jcm.29.2.398-400.1991.
During the use of a single lot of custom breakpoint panels (Sensititre; Radiometer America Inc., Westlake, Ohio), imipenem susceptibility declined from 70 to 44% for clinical isolates of Pseudomonas aeruginosa. With a new lot, susceptibility increased to 73%. Subsequent evaluations with P. aeruginosa ATCC 27853 revealed a similar susceptibility pattern and an increase in the MIC of imipenem when determined in panels with increasing ages. Imipenem concentrations were determined by high-performance liquid chromatography by using 11 different lots of MIC and breakpoint panels (139 to 893 days of age). The amount of imipenem remaining declined from 94.4 to 13.8% (r = 0.9225) over the age range of the panels. These data suggest that imipenem in Sensititre MIC and breakpoint panels degrades over time and that the decrease in imipenem may be largely responsible for the decline in P. aeruginosa susceptibility.
在使用一批定制的药敏折点板(Sensititre;美国 Radiometer 公司,俄亥俄州韦斯特莱克)期间,铜绿假单胞菌临床分离株对亚胺培南的敏感性从 70%降至 44%。使用新的一批折点板后,敏感性升至 73%。随后对铜绿假单胞菌 ATCC 27853 进行的评估显示出类似的敏感性模式,并且在使用不同批次的折点板(板龄逐渐增加)测定时,亚胺培南的最低抑菌浓度(MIC)有所增加。通过高效液相色谱法,使用 11 个不同批次的 MIC 和折点板(板龄 139 至 893 天)测定亚胺培南浓度。在所测试的折点板龄范围内,亚胺培南的剩余量从 94.4%降至 13.8%(r = 0.9225)。这些数据表明,Sensititre MIC 和折点板中的亚胺培南会随时间降解,亚胺培南的减少可能是铜绿假单胞菌敏感性下降的主要原因。