Extracellular volume measurements using bioimpedance spectroscopy-Hanai method and wrist-ankle resistance at 50 kHz.

作者信息

Jaffrin Michel Y, Morel Hélène

机构信息

Department of Biological Engineering, UMR CNRS 6600, Technological University of Compiegne, BP 20529, 60205 Compiegne Cedex, France.

出版信息

Med Biol Eng Comput. 2009 Jan;47(1):77-84. doi: 10.1007/s11517-008-0394-z. Epub 2008 Sep 17.

Abstract

A method for extrapolating the extracellular water (ECW) resistance from wrist-ankle resistance at 50 kHz (R (50)) is proposed in this paper, in order to enable 50 kHz impedancemeters to use the BIS-Hanai equation for determination of ECW. Values of R (50) and the ECW resistance extrapolated at zero frequency R (e) were measured in a first group of 57 healthy volunteers, using a Xitron 4200 multifrequency impedancemeter and mean values (b) of the ratio R (50)/R (e) in men and women were used to determine individual values of R (e50), the ECW resistance extrapolated from R (50), which were substituted to R (e) in the BIS-Hanai equation. For validation, the method was compared against ECW measured with the Xitron (V (ex)) in a second group of 31 healthy volunteers, using values of b of first group. Values of R (e50) in this second group were found to be not significantly different from corresponding values of R (e) with p-values of Student test of 0.346 for men and 0.300 for women. ECW volumes (V (e50)) calculated from R (e50) were also found not significantly different from those of the Xitron with Student paired test p values of 0.277 in men and 0.393 in women. Our method gave a better agreement with V (ex) than two bioimpedance analysis methods from the literature, especially in women. It was also tested on a 50 kHz single frequency impedancemeter (BodyExplorer, Juwell Medical) on a third group of 21 subjects and gave ECW volumes not significantly from those of the Xitron with p = 0.531 for men and 0.096 for women.

摘要

本文提出了一种从50kHz时的手腕-脚踝电阻(R(50))推断细胞外液(ECW)电阻的方法,以使50kHz阻抗计能够使用BIS-Hanai方程来测定ECW。在第一组57名健康志愿者中,使用Xitron 4200多频阻抗计测量R(50)的值以及在零频率时推断出的ECW电阻R(e),并使用男性和女性中R(50)/R(e)比值的平均值(b)来确定从R(50)推断出的R(e50)的个体值,该值被代入BIS-Hanai方程中的R(e)。为了进行验证,在第二组31名健康志愿者中,使用第一组的b值,将该方法与用Xitron测量的ECW(V(ex))进行比较。发现该第二组中R(e50)的值与相应的R(e)值没有显著差异,男性的学生检验p值为0.346,女性为0.300。由R(e50)计算出的ECW体积(V(e50))与Xitron测量的体积也没有显著差异,男性的学生配对检验p值为0.277,女性为0.393。与文献中的两种生物电阻抗分析方法相比,我们的方法与V(ex)的一致性更好,尤其是在女性中。该方法还在第三组21名受试者身上用50kHz单频阻抗计(BodyExplorer,久维医疗)进行了测试,得出的ECW体积与Xitron测量的体积没有显著差异,男性的p值为0.531,女性为0.096。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验