Suppr超能文献

6D 图像引导下的脊柱非侵入性立体定向体部放射治疗:ExacTrac X 射线 6D 与千伏锥形束 CT 的比较。

6D image guidance for spinal non-invasive stereotactic body radiation therapy: Comparison between ExacTrac X-ray 6D with kilo-voltage cone-beam CT.

机构信息

Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710, USA.

出版信息

Radiother Oncol. 2010 Apr;95(1):116-21. doi: 10.1016/j.radonc.2009.12.036. Epub 2010 Feb 1.

Abstract

PURPOSE

To investigate setup discrepancies measured with ExacTrac X-ray 6 degree-of-freedom (6D) and cone-beam computed tomography (CBCT) for patients under treatments of stereotactic body radiation therapy (SBRT).

MATERIALS AND METHODS

In this work, phantom and patient studies were performed. In the phantom studies, an anthropomorphic phantom was placed with pre-defined positions, and imaged with ExacTrac X-ray 6D and CBCT to test the accuracy of the imaging systems. In the patient studies, 16 spinal SBRT patient cases were retrospectively analyzed. The patients were initially positioned in customized immobilization cradles and then aligned with ExacTrac X-ray 6D and CBCT. The setup discrepancies were computed and quantitatively analyzed.

RESULTS

This study indicates modest discrepancies between ExacTrac X-ray 6D and CBCT with spinal SBRT. The phantom experiments showed that translational and rotational discrepancies in root-mean-square (RMS) between ExacTrac X-ray 6D and CBCT were, respectively, <1.0mm and <1 degrees . In the retrospective patient studies, translational and rotational discrepancies in RMS between ExacTrac X-ray 6D and CBCT were <2.0mm and <1.5 degrees .

CONCLUSIONS

ExacTrac X-ray 6D represents a potential alternative to CBCT; however, pre-caution should be taken when only ExacTrac X-ray 6D is used to guide SBRT with small setup margins.

摘要

目的

研究使用 ExacTrac X 射线 6 自由度(6D)和锥形束计算机断层扫描(CBCT)测量的立体定向体部放射治疗(SBRT)患者的摆位误差。

材料和方法

本研究进行了体模和患者研究。在体模研究中,将解剖体模放置在预定义的位置,并使用 ExacTrac X 射线 6D 和 CBCT 进行成像,以测试成像系统的准确性。在患者研究中,回顾性分析了 16 例脊柱 SBRT 患者。患者最初在定制的固定架中定位,然后使用 ExacTrac X 射线 6D 和 CBCT 进行对准。计算了摆位误差并进行了定量分析。

结果

本研究表明,脊柱 SBRT 中 ExacTrac X 射线 6D 和 CBCT 之间存在适度的差异。体模实验表明,ExacTrac X 射线 6D 和 CBCT 之间的平移和旋转 RMS 差异分别小于 1.0mm 和小于 1 度。在回顾性患者研究中,ExacTrac X 射线 6D 和 CBCT 之间的平移和旋转 RMS 差异小于 2.0mm 和小于 1.5 度。

结论

ExacTrac X 射线 6D 代表了 CBCT 的潜在替代方案;然而,当仅使用 ExacTrac X 射线 6D 引导具有较小摆位余量的 SBRT 时,应谨慎行事。