运动测试方案对有氧功能参数的影响。

Effect of exercise testing protocol on parameters of aerobic function.

作者信息

Zhang Y Y, Johnson M C, Chow N, Wasserman K

机构信息

Division of Respiratory and Critical Care Physiology, Harbor-UCLA Medical Center, Torrance 90509.

出版信息

Med Sci Sports Exerc. 1991 May;23(5):625-30.

PMID:2072842
Abstract

Four different patterns of increasing work rate (ramp and 1-min, 2-min, and 3-min steps) to maximum tolerance were studied in eight normal male subjects during cycle ergometer exercise testing to determine the effect of the work rate protocol on the parameters of aerobic function. The overall rate of work rate increase was kept constant. Measurements included VO2max, anaerobic threshold (AT), and the O2 uptake increase with respect to work rate increase (delta VO2/delta WR). VO2, VCO2, VE, respiratory exchange ratio (R), PETCO2, and PETO2 were calculated breath-by-breath. No significant difference was found in VO2max, AT, AT/VO2max, and delta VO2/delta WR among the four work rate protocols. Other measurements such as total work, maximal work rate, VCO2, VE, R, HR, O2 pulse, and the VO2 at which VE increases disproportionately to VCO2 (ventilatory compensation point) were also similar among the four protocols. Both the ramp and 1-min step work rate tests had no step pattern in either VO2 or VCO2, and the step pattern for the 2-min and 3-min step tests was attenuated or disappeared at work rates above AT. We conclude that the parameters of aerobic function, and other physiological responses at maximum work rate, were independent of the pattern of work rate increase, provided that the overall rate of work rate increase was the same.

摘要

在八名正常男性受试者进行自行车测力计运动测试期间,研究了四种不同的增加工作率模式(斜坡模式以及1分钟、2分钟和3分钟的阶梯模式)直至最大耐受程度,以确定工作率方案对有氧功能参数的影响。工作率的总体增加速率保持恒定。测量指标包括最大摄氧量(VO2max)、无氧阈(AT)以及摄氧量随工作率增加的增加量(δVO2/δWR)。逐次呼吸计算VO2、VCO2、VE、呼吸交换率(R)、呼气末二氧化碳分压(PETCO2)和呼气末氧分压(PETO2)。在四种工作率方案中,VO2max、AT、AT/VO2max和δVO2/δWR未发现显著差异。其他测量指标,如总功、最大工作率、VCO2、VE、R、心率(HR)、氧脉搏以及VE与VCO2不成比例增加时的VO2(通气补偿点),在四种方案中也相似。斜坡模式和1分钟阶梯模式的工作率测试在VO2或VCO2中均无阶梯模式,2分钟和3分钟阶梯模式测试的阶梯模式在高于AT的工作率时减弱或消失。我们得出结论,只要工作率的总体增加速率相同,有氧功能参数以及最大工作率时的其他生理反应与工作率增加模式无关。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验