使用锥形束计算机断层扫描和两种物体倾斜度进行线性下颌骨测量的可靠性和可重复性。

Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations.

机构信息

Department of Periodontology, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Sweden.

出版信息

Dentomaxillofac Radiol. 2011 May;40(4):244-50. doi: 10.1259/dmfr/17432330.

Abstract

OBJECTIVE

The aim of this study was to assess the influence of inclination of the object on the reliability and reproducibility of linear measurements of anatomic structures of the mandible on images obtained using cone-beam CT (CBCT).

METHODS

Ten linear dimensions between anatomical landmarks were measured in a dry mandible. The measurements were performed with a manual calliper three times by three observers. The mandible was scanned with Planmeca Promax 3D cone-beam CT (Planmeca Oy, Helsinki, Finland) with the base of the mandible parallel as well as tilted 45° to the horizontal plane. Computer measurements of the linear dimension were performed by three observers. The radiographic measurements were performed four times for each experimental setting. A total of 240 measurements were performed. Reproducibility was evaluated through comparison of standard deviation (SD) and estimation of intraclass correlation coefficient (ICC). The error was estimated as the absolute difference between the radiographic measurements and the mean manual calliper measurements.

RESULTS

The mean SD for the radiographic measurements was 0.36 mm for the horizontally positioned mandible and 0.48 mm for the inclined mandible. The ICC between examiners was 0.996 mm, between sessions was 0.990 mm and between CBCT measurements and calliper was 0.992 mm. The overall absolute mean measurement error was 0.40 mm (SD 0.39 mm). The percentage of errors that exceeded 1 mm was 6.7%.

CONCLUSION

The results revealed high reliability of measurements performed on CBCT images independently from object position, examiner's experience and high reproducibility in repeated measurements settings.

摘要

目的

本研究旨在评估物体倾斜对使用锥形束 CT(CBCT)获得的下颌骨解剖结构线性测量的可靠性和可重复性的影响。

方法

在干燥的下颌骨上测量了 10 个解剖标志之间的线性尺寸。由 3 名观察者使用手动卡尺进行了 3 次测量。使用 Planmeca Promax 3D 锥形束 CT(芬兰赫尔辛基 Planmeca Oy)对下颌骨进行扫描,下颌骨底部与水平面平行以及倾斜 45°。由 3 名观察者通过计算机进行线性尺寸的测量。对于每种实验设置,均进行了 4 次放射测量。总共进行了 240 次测量。通过比较标准偏差(SD)和估计组内相关系数(ICC)来评估可重复性。将放射测量与手动卡尺平均值之间的绝对差值作为误差进行估计。

结果

水平放置的下颌骨的放射测量平均 SD 为 0.36mm,倾斜的下颌骨的 SD 为 0.48mm。观察者之间的 ICC 为 0.996mm,检查之间的 ICC 为 0.990mm,CBCT 测量值与卡尺之间的 ICC 为 0.992mm。总体平均绝对测量误差为 0.40mm(SD 为 0.39mm)。误差超过 1mm 的百分比为 6.7%。

结论

结果表明,无论物体位置、检查者的经验如何,使用 CBCT 图像进行的测量均具有高度可靠性,并且在重复测量设置中具有高度可重复性。

相似文献

引用本文的文献

本文引用的文献

9
Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging.一种新开发的用于颌面成像的锥形束设备的几何精度。
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 Oct;104(4):551-9. doi: 10.1016/j.tripleo.2007.02.021. Epub 2007 Jul 5.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验