Abstract

Many of the target molecules that reside in blood are also present in oral fluids, albeit at lower concentrations. Oral fluids are, however, relatively easy and safe to collect without the need for specialized equipment and training. Thus, oral fluids provide convenient samples for medical diagnostics. Recent advances in lab-on-a-chip technologies have made minute, fully integrated diagnostic systems practical for an assortment of point-of-care tests. Such systems can perform either immunoassays or molecular diagnostics outside centralized laboratories within time periods ranging from minutes to an hour. The article briefly reviews recent advances in devices for point-of-care testing with a focus on work that has been carried out by the authors as part of a NIH program.

摘要

许多存在于血液中的靶分子也存在于口腔液中,尽管浓度较低。然而,口腔液相对容易收集,且无需专门的设备和培训,因此,口腔液为医疗诊断提供了方便的样本。微流控芯片技术的最新进展使得微小、完全集成的诊断系统可用于各种即时检测。这些系统可以在几分钟到一个小时的时间内,在集中式实验室之外进行免疫测定或分子诊断。本文简要回顾了即时检测设备的最新进展,重点介绍了作者作为 NIH 计划的一部分所开展的工作。

相似文献

1
Point-of-care oral-based diagnostics.
Oral Dis. 2011 Nov;17(8):745-52. doi: 10.1111/j.1601-0825.2011.01808.x. Epub 2011 Apr 26.
2
Translational and clinical applications of salivary diagnostics.
Adv Dent Res. 2011 Oct;23(4):375-80. doi: 10.1177/0022034511420434.
3
Microfluidic "Pouch" Chips for Immunoassays and Nucleic Acid Amplification Tests.
Methods Mol Biol. 2017;1572:467-488. doi: 10.1007/978-1-4939-6911-1_30.
4
A review of digital microfluidics as portable platforms for lab-on a-chip applications.
Lab Chip. 2016 Jul 7;16(13):2376-96. doi: 10.1039/c6lc00387g. Epub 2016 Jun 8.
5
Integrated microfluidic platform for oral diagnostics.
Ann N Y Acad Sci. 2007 Mar;1098:362-74. doi: 10.1196/annals.1384.004.
6
Lab-on-a-Disc for Point-of-Care Infection Diagnostics.
Acc Chem Res. 2021 Oct 5;54(19):3643-3655. doi: 10.1021/acs.accounts.1c00367. Epub 2021 Sep 13.
7
Immunoassay-based diagnostic point-of-care technology for oral specimen.
Ann N Y Acad Sci. 2007 Mar;1098:486-9. doi: 10.1196/annals.1384.017.
8
On-Chip Magnetic Particle-Based Immunoassays Using Multilaminar Flow for Clinical Diagnostics.
Methods Mol Biol. 2017;1547:69-83. doi: 10.1007/978-1-4939-6734-6_6.
9
Lab-on-a-Chip Devices for Point-of-Care Medical Diagnostics.
Adv Biochem Eng Biotechnol. 2022;179:247-265. doi: 10.1007/10_2020_127.
10
Saliva-based microfluidic point-of-care diagnostic.
Theranostics. 2023 Jan 31;13(3):1091-1108. doi: 10.7150/thno.78872. eCollection 2023.

引用本文的文献

2
Sample Preparation and Diagnostic Methods for a Variety of Settings: A Comprehensive Review.
Molecules. 2021 Sep 18;26(18):5666. doi: 10.3390/molecules26185666.
3
Engineered Ultra-High Affinity Synthetic Antibodies for SARS-CoV-2 Neutralization and Detection.
J Mol Biol. 2021 May 14;433(10):166956. doi: 10.1016/j.jmb.2021.166956. Epub 2021 Mar 26.
4
An immunoassay cassette with a handheld reader for HIV urine testing in point-of-care diagnostics.
Biomed Microdevices. 2020 May 21;22(2):39. doi: 10.1007/s10544-020-00494-4.
5
Salivary biomarker for acute appendicitis in children: a pilot study.
Pediatr Surg Int. 2020 May;36(5):621-627. doi: 10.1007/s00383-020-04645-9. Epub 2020 Mar 26.
6
Association of mRNA Levels of IL6, MMP-8, GSS in Saliva and Pyelonephritis in Children.
Molecules. 2019 Dec 25;25(1):85. doi: 10.3390/molecules25010085.
8
Point-of-care microfluidic devices for pathogen detection.
Biosens Bioelectron. 2018 Oct 15;117:112-128. doi: 10.1016/j.bios.2018.05.050. Epub 2018 May 29.
9
Salivary Diagnostics in Pediatrics: Applicability, Translatability, and Limitations.
Front Public Health. 2017 Apr 20;5:83. doi: 10.3389/fpubh.2017.00083. eCollection 2017.
10
Instrument-Free Point-of-Care Molecular Detection of Zika Virus.
Anal Chem. 2016 Jul 19;88(14):7289-94. doi: 10.1021/acs.analchem.6b01632. Epub 2016 Jun 29.

本文引用的文献

1
A Portable Analyzer for Pouch-Actuated, Immunoassay Cassettes.
Sens Actuators B Chem. 2011 Dec 15;160(1):1529-1535. doi: 10.1016/j.snb.2011.08.012.
2
Estimating the clinical impact of bringing a multimarker cardiac panel to the bedside in the ED.
Am J Emerg Med. 2011 Sep;29(7):813-4. doi: 10.1016/j.ajem.2011.01.003.
4
Saliva as a diagnostic fluid.
Dent Clin North Am. 2011 Jan;55(1):159-78. doi: 10.1016/j.cden.2010.08.004.
5
Microfluidic compartmentalized directed evolution.
Chem Biol. 2010 Jul 30;17(7):717-24. doi: 10.1016/j.chembiol.2010.05.021.
6
A PCR reactor with an integrated alumina membrane for nucleic acid isolation.
Analyst. 2010 Sep;135(9):2408-14. doi: 10.1039/c0an00288g. Epub 2010 Jul 9.
7
8
Perspectives on cost and outcomes for point-of-care testing.
Clin Lab Med. 2009 Sep;29(3):479-89. doi: 10.1016/j.cll.2009.07.001.
9
Single bead-based electrochemical biosensor.
Biosens Bioelectron. 2009 Dec 15;25(4):809-14. doi: 10.1016/j.bios.2009.08.033. Epub 2009 Aug 28.
10
Microfluidic, bead-based assay: Theory and experiments.
J Chromatogr B Analyt Technol Biomed Life Sci. 2010 Jan 15;878(2):228-36. doi: 10.1016/j.jchromb.2009.08.050. Epub 2009 Sep 4.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验