预置托槽的转矩值是否精确?

Are torque values of preadjusted brackets precise?

机构信息

Department of Orthodontics, Dental School, University of São Paulo, São Paulo, SP, Brazil.

出版信息

J Appl Oral Sci. 2011 Aug;19(4):313-7. doi: 10.1590/s1678-77572011005000003. Epub 2011 May 27.

Abstract

OBJECTIVE

The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands.

MATERIAL AND METHODS

Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription.

RESULTS

The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands.

CONCLUSIONS

There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.

摘要

目的

本研究旨在验证 MBT 矫治器中金属托槽的转矩精度,选用方丝弓托槽作为 6 个商业品牌的代表样本。

材料与方法

选取以下商业品牌之一的 20 个上颌和 20 个下颌尖牙托槽:3M Unitek、Abzil、American Orthodontics、TP Orthodontics、Morelli 和 Ortho Organizers。通过操作员使用连接计算机的光学显微镜测量参考点和线确定的转矩角度。将这些值与 MBT 处方中确定的值进行比较。

结果

结果表明,对于上颌尖牙托槽,只有 Morelli 转矩(-3.33°)与建议值(-7°)存在统计学差异。对于下颌尖牙,American Orthodontics(-6.34°)和 Ortho Organizers(-6.25°)与标准值(-6°)存在统计学差异。在品牌之间进行比较时,与其他所有品牌相比,Morelli 在上颌尖牙托槽方面存在统计学差异。对于下颌尖牙托槽,各品牌之间没有统计学差异。

结论

评估的一些托槽转矩值存在显著差异,这将在临床治疗结束时影响牙齿颊舌向位置。