Suppr超能文献

利用微计算机断层扫描(Micro-CT)评估陶瓷正畸托槽槽尺寸的准确性和精密度。

An Evaluation of the Accuracy and Precision of Ceramic Orthodontic Bracket Slot Dimensions Utilizing Micro-Computed Tomography (Micro-CT).

机构信息

Faculty of Dentistry, BPP University, 32-34 Colmore Circus Queensway, Birmingham B4 6BN, UK.

Restorative and Prosthetic Dental Sciences Department, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences (KSAU-HS), Riyadh 11426, Saudi Arabia.

出版信息

Tomography. 2023 Jul 13;9(4):1369-1380. doi: 10.3390/tomography9040109.

Abstract

This study's aim is to determine the accuracy and precision of the bracket slot height in MBT 0.022″ ceramic brackets. Five brackets from 11 different systems (n = 55) were scanned using micro-computed tomography (micro-CT). The slot height was measured at the face (external) and base (internal) of the slot. Data were analyzed using a One-Sample -Test, and a Paired -Test. The lowest external height was seen in OrthoCare Purity at 0.02264″ (2.9%), and the greatest in TOC Ghost Advanced at 0.02736″ (24.4%). The lowest internal height was seen in Forestadent Glam at 0.02020″ (-8.2%), and the greatest in TOC Ghost Advanced at 0.2547″ (15.8%). OrthoCare Purity measurements corresponded most closely with the expected measurements. TP InVu was found to be the most precise bracket for external height (range = 0.00043″) and American Orthodontics 20/40 for internal height (range = 0.00028″). In assessing slot geometry, all brackets demonstrated a higher mean external slot height compared to the internal measurements at the base of the bracket. Orthodontic bracket slots are larger than expected and slot parallelism was not observed in any bracket brand tested. Similarly, slot dimensions are imprecise where two 'identical' brackets have different slot sizes. The clinician should, therefore, assume that play is most likely higher than expected.

摘要

本研究旨在确定 MBT 0.022″陶瓷托槽的槽高精度和准确性。使用微计算机断层扫描(micro-CT)对来自 11 个不同系统的 5 个托槽(n = 55)进行扫描。在槽的面(外部)和底(内部)测量槽高。使用单样本检验和配对检验对数据进行分析。外部最小高度见于 OrthoCare Purity 为 0.02264″(2.9%),最大见于 TOC Ghost Advanced 为 0.02736″(24.4%)。内部最小高度见于 Forestadent Glam 为 0.02020″(-8.2%),最大见于 TOC Ghost Advanced 为 0.2547″(15.8%)。OrthoCare Purity 的测量结果与预期测量结果最接近。TP InVu 被发现是外部高度最精确的托槽(范围=0.00043″),而 American Orthodontics 20/40 则是内部高度最精确的托槽(范围=0.00028″)。在评估槽几何形状时,所有托槽的外部槽高平均值均高于托槽底部的内部测量值。与预期相比,正畸托槽槽的高度更大,且在测试的任何托槽品牌中都未观察到槽的平行度。同样,槽尺寸也不精确,两个“相同”的托槽具有不同的槽尺寸。因此,临床医生应假设间隙可能比预期的更大。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/99b0/10366895/3d72678dbe4e/tomography-09-00109-g001.jpg