Suppr超能文献

用于天体物理和医学应用的 CdTe 和 CdZnTe 半导体辐射探测器的发展进展。

Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications.

机构信息

INAF/IASF Palermo, Via Ugo La Malfa 153, 90146 Palermo, Italy.

出版信息

Sensors (Basel). 2009;9(5):3491-526. doi: 10.3390/s90503491. Epub 2009 May 12.

Abstract

Over the last decade, cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors have attracted increasing interest as X-ray and gamma ray detectors. Among the traditional high performance spectrometers based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show high detection efficiency and good room temperature performance and are well suited for the development of compact and reliable detection systems. In this paper, we review the current status of research in the development of CdTe and CdZnTe detectors by a comprehensive survey on the material properties, the device characteristics, the different techniques for improving the overall detector performance and some major applications. Astrophysical and medical applications are discussed, pointing out the ongoing Italian research activities on the development of these detectors.

摘要

在过去的十年中,碲化镉(CdTe)和碲化镉锌(CdZnTe)宽带隙半导体作为 X 射线和伽马射线探测器引起了越来越多的关注。在基于硅(Si)和锗(Ge)的传统高性能光谱仪中,CdTe 和 CdZnTe 探测器具有高探测效率和良好的室温性能,非常适合开发紧凑可靠的检测系统。在本文中,我们通过对材料性能、器件特性、提高整体探测器性能的不同技术以及一些主要应用的综合调查,综述了 CdTe 和 CdZnTe 探测器的研究现状。讨论了天体物理和医学应用,指出了意大利在开发这些探测器方面的正在进行的研究活动。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dff2/3297127/9fe21e713034/sensors-09-03491f1.jpg

相似文献

2
Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications.
Nucl Instrum Methods Phys Res A. 2015 Jun 1;784:531-537. doi: 10.1016/j.nima.2014.10.079.
3
Polycrystalline CdZnTe thick films for low energy x-ray: system evaluation.
Conf Proc IEEE Eng Med Biol Soc. 2006;2006:1990-3. doi: 10.1109/IEMBS.2006.260666.
5
Characterization of the Uniformity of High-Flux CdZnTe Material.
Sensors (Basel). 2020 May 12;20(10):2747. doi: 10.3390/s20102747.
6
Recent advances in the development of high-resolution 3D cadmium-zinc-telluride drift strip detectors.
J Synchrotron Radiat. 2020 Nov 1;27(Pt 6):1564-1576. doi: 10.1107/S1600577520010747. Epub 2020 Sep 25.
7
Optimizing timing performance of CdTe detectors for PET.
Phys Med Biol. 2017 Sep 12;62(19):N485-N505. doi: 10.1088/1361-6560/aa8664.
8
Charge Sharing and Charge Loss in High-Flux Capable Pixelated CdZnTe Detectors.
Sensors (Basel). 2021 May 8;21(9):3260. doi: 10.3390/s21093260.
9
Development of a gamma ray monitor using a CdZnTe semiconductor detector.
Radiat Prot Dosimetry. 2002;101(1-4):77-80. doi: 10.1093/oxfordjournals.rpd.a006063.
10
Fabrication of Small-Pixel CdZnTe Sensors and Characterization with X-rays.
Sensors (Basel). 2021 Apr 22;21(9):2932. doi: 10.3390/s21092932.

引用本文的文献

1
Multimodal characterization of Te inclusions in CdZnTe and CdZnTeSe for gamma and X-ray detectors.
Sci Rep. 2025 Aug 30;15(1):31996. doi: 10.1038/s41598-025-15132-3.
2
Applications of Cd(Zn)Te Radiation Detectors in Non-Destructive Testing and Evaluation.
Sensors (Basel). 2025 Mar 13;25(6):1776. doi: 10.3390/s25061776.
3
Highly stable bismuth-chloride perovskite X-ray direct detectors with an ultralow detection limit.
Chem Sci. 2025 Feb 13;16(11):4768-4774. doi: 10.1039/d5sc00061k. eCollection 2025 Mar 12.
4
A Simulation Study for Optimal Pinhole Collimator Design in Gamma Camera Systems.
J Med Phys. 2024 Oct-Dec;49(4):648-653. doi: 10.4103/jmp.jmp_127_24. Epub 2024 Dec 18.
6
First Stability Characterization for a CZT Detection System in an ee Collider Environment.
Sensors (Basel). 2024 Nov 27;24(23):7562. doi: 10.3390/s24237562.
7
Revolutionizing X-ray Imaging: A Leap toward Ultra-Low-Dose Detection with a Cascade-Engineered Approach.
ACS Cent Sci. 2024 Nov 13;10(11):2082-2089. doi: 10.1021/acscentsci.4c01296. eCollection 2024 Nov 27.
9
Research on the Technological Progress of CZT Array Detectors.
Sensors (Basel). 2024 Jan 23;24(3):725. doi: 10.3390/s24030725.
10
[Not Available].
Nucl Med Mol Imaging. 2024 Feb;58(1):1-8. doi: 10.1007/s13139-023-00825-2. Epub 2023 Sep 26.

本文引用的文献

1
Polarized gamma-ray emission from the crab.
Science. 2008 Aug 29;321(5893):1183-5. doi: 10.1126/science.1149056.
2
Recent developments in PET detector technology.
Phys Med Biol. 2008 Sep 7;53(17):R287-317. doi: 10.1088/0031-9155/53/17/R01. Epub 2008 Aug 11.
4
Thin CdTe detector in diagnostic x-ray spectroscopy.
Med Phys. 2003 May;30(5):771-7. doi: 10.1118/1.1566388.
5
CdZnTe detector in diagnostic x-ray spectroscopy.
Med Phys. 2002 Jul;29(7):1421-9. doi: 10.1118/1.1485975.
6
Charge transport in arrays of semiconductor gamma-ray detectors.
Phys Rev Lett. 1995 Jul 3;75(1):156-159. doi: 10.1103/PhysRevLett.75.156.
7
Comparison of x-ray cross sections for diagnostic and therapeutic medical physics.
Med Phys. 1996 Dec;23(12):1997-2005. doi: 10.1118/1.597899.
8
Measurement of diagnostic x-ray spectra using a silicon photodiode.
Med Phys. 1989 Jul-Aug;16(4):529-36. doi: 10.1118/1.596354.
9
Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector.
Phys Med Biol. 1979 May;24(3):505-17. doi: 10.1088/0031-9155/24/3/002.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验