使用双光散射系统测量客观散射指数对核性、皮质性和后囊下白内障进行分级。

Grading nuclear, cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system.

机构信息

Centre de Desenvolupament de Sensors, Instrumentació i Sistemes (CD6), Universitat Politècnica de Catalunya, Rambla Sant Nebridi 10, 08222 Terrassa, Barcelona, Spain.

出版信息

Br J Ophthalmol. 2012 Sep;96(9):1204-10. doi: 10.1136/bjophthalmol-2011-301055. Epub 2012 Jul 11.

Abstract

PURPOSE

To evaluate objectively intraocular scattering in eyes with nuclear, cortical and posterior subcapsular cataracts by means of an objective scatter index (OSI) obtained from double-pass images. To compare the results with those obtained using clinical conventional procedures.

METHODS

In this prospective, observational, cross-sectional, non-consecutive case series study, 188 eyes with cataracts of 136 patients were analysed (123 eyes had nuclear, 41 eyes had cortical and 24 eyes had posterior subcapsular cataracts). The control group consisted of 117 eyes of 68 healthy patients. Patient examination included subjective refraction, best spectacle-corrected visual acuity (BSCVA), cataract grade using the lens opacities classification system III (LOCS III) and OSI.

RESULTS

We found a decrease in the BSCVA and an increase in the OSI with increasing cataract grade. Statistically significant differences were observed when the OSI of eyes without cataracts and those with different LOCS III were compared. The comparison between the OSI and LOCS III reported good percentages of agreement regarding the number of eyes classified in equivalent levels: 72.4% (nuclear cataracts), 86.6% (cortical cataracts) and 84.3% (posterior subcapsular cataracts). A non-linear regression model was applied between OSI and BSCVA, which resulted in the following multiple correlation coefficients: r=0.878 (nuclear), r=0.843 (cortical) and r=0.844 (posterior subcapsular).

CONCLUSIONS

The results of the study showed that OSI is a useful parameter for evaluating large amounts of intraocular scattering that can be used, in combination with other conventional procedures, as a valuable tool in clinical practice to grade cataracts objectively.

摘要

目的

通过双光散射图像获得的客观散射指数(OSI)客观评估核性、皮质性和后囊下白内障眼的眼内散射。将结果与使用临床常规程序获得的结果进行比较。

方法

在这项前瞻性、观察性、横断面、非连续病例系列研究中,分析了 136 名患者的 188 只白内障眼(123 只眼为核性白内障,41 只眼为皮质性白内障,24 只眼为后囊下白内障)。对照组由 68 名健康患者的 117 只眼组成。患者检查包括主观验光、最佳矫正视力(BSCVA)、使用晶状体混浊分类系统 III(LOCS III)评估的白内障分级和 OSI。

结果

随着白内障分级的增加,BSCVA 降低,OSI 增加。当比较无白内障眼和不同 LOCS III 眼的 OSI 时,观察到统计学上的显著差异。OSI 与 LOCS III 的比较报告了在等效水平分类的眼数方面具有良好的一致性百分比:72.4%(核性白内障)、86.6%(皮质性白内障)和 84.3%(后囊下白内障)。OSI 和 BSCVA 之间应用了非线性回归模型,得到以下多元相关系数:r=0.878(核性)、r=0.843(皮质性)和 r=0.844(后囊下)。

结论

研究结果表明,OSI 是评估大量眼内散射的有用参数,可与其他常规程序结合使用,作为临床实践中客观分级白内障的有价值工具。